Key result
The REG1 anticoagulation system (factor IXa inhibitor RB006 and reversal agent RB007) was successfully used during PCI, with 10% ischemic events in the REG1 group versus 25% with heparin.
Why the study?
Does the REG1 system (RB006 and RB007) provide safe and effective actively reversible anticoagulation compared to unfractionated heparin in patients undergoing percutaneous coronary intervention?
RCT (n=26)
5:1
Does the REG1 system (RB006 and RB007) provide safe and effective actively reversible anticoagulation compared to unfractionated heparin in patients undergoing percutaneous coronary intervention?
Absolute Event Rate: 10% vs 25%
The REG1 system (factor IXa inhibitor RB006 and its reversal agent RB007) provides a feasible, actively reversible anticoagulation strategy for patients undergoing PCI.
Enables active reversal during PCI; extends targeted factor IXa inhibition as alternative to heparin in randomized settings.
BACKGROUND: The ideal anticoagulant should prevent ischemic complications without increasing the risk of bleeding. Controlled anticoagulation is possible with the REG1 system, an RNA aptamer pair comprising the direct factor IXa inhibitor RB006 and its active control agent RB007. METHODS AND RESULTS: This phase 2a study included a roll-in group (n=2) treated with REG1 plus glycoprotein IIb/IIIa inhibitors followed by 2 groups randomized 5:1 to REG1 or unfractionated heparin. In group 1 (n=12), RB006 was partially reversed with RB007 after percutaneous coronary intervention and fully reversed 4 hours later. In group 2 (n=12), RB006 was fully reversed with RB007 immediately after percutaneous coronary intervention. Femoral sheaths were removed after complete reversal. Patients were pretreated with aspirin and clopidogrel. End points included major bleeding within 48 hours; composite of death, myocardial infarction, or urgent target vessel revascularization within 14 days; and pharmacodynamic measures. All cases were successful, with final Thrombolysis in Myocardial Infarction grade 3 flow and no angiographic thrombotic complications. There were 2 ischemic end points in the REG1 group and 1 in the unfractionated heparin group, with 1 major bleed in the unfractionated heparin group. Median activated clotting time values rose from 151 to 236 seconds after RB006. Administration of the partial RB007 dose reversed anticoagulation to an intermediate activated clotting time value of 186 seconds. Complete reversal with RB007 returned the median activated clotting time value to 144 seconds. Both reversal strategies enabled scheduled femoral sheath removal. CONCLUSIONS: This study demonstrates the clinical translation of a novel platform of anticoagulation targeting factor IXa and its active reversal to percutaneous coronary intervention and provides the basis for further investigation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00715455.
No takes yet. Share an insight, caveat, or question.
Cohen et al. (2010) conducted an RCT in Percutaneous Coronary Intervention (n=26). REG1 system (RB006 and RB007) vs. unfractionated heparin was evaluated on composite of death, myocardial infarction, or urgent target vessel revascularization within 14 days. The REG1 anticoagulation system (factor IXa inhibitor RB006 and reversal agent RB007) was successfully used during PCI, with 10% ischemic events in the REG1 group versus 25% with heparin.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: