Why the study?
Four-dimensional flow cardiovascular MRI has emerged for assessing aortic stenosis, but its agreement with transthoracic echocardiography in estimating peak velocities, grading severity, and predicting aortic valve intervention in real-world settings needed evaluation.
Does 4D flow CMR improve the prediction of aortic valve intervention compared to transthoracic echocardiography in patients with aortic stenosis?
Observational (n=30)
Does 4D flow CMR improve the prediction of aortic valve intervention compared to transthoracic echocardiography in patients with aortic stenosis?
4D flow CMR provides incremental diagnostic value over standard echocardiography by better predicting the need for aortic valve intervention in patients with aortic stenosis.
Answers are grounded in this paper and cite their sources.
4D flow CMR peak velocity may aid aortic stenosis risk stratification beyond echocardiography; leaves open need for prospective validation before clinical adoption.
Aims Four-dimensional flow cardiovascular MRI (4D flow CMR) has emerged as a promising technique for assessing aortic stenosis (AS). This study aimed to evaluate the agreement between 4D flow CMR and transthoracic echocardiography (TTE) in estimating peak aortic valve (AV) velocities (V Peak ), grading AS severity and predicting AV intervention in a real-world setting. Methods Participants from the PREFER-CMR registry who had consecutive TTE and 4D flow CMR were included. AS severity was graded using established protocols using three echocardiographic parameters (V Peak , AV area and mean pressure gradient) and CMR-derived V Peak . Results The study recruited 30 patients (mean age 75.4 years, 67% male), with 17 undergoing AV intervention. Continuous wave Doppler (CWD) V Peak (3.4 vs 2.6 m/s, p=0.0025) and 4D flow V Peak (4.2 vs 2.7 m/s, p<0.0001) were significantly higher in patients going for AV intervention. V Peak by CWD was significantly lower to 4D flow with a bias of −0.5 (p=0.01) and a correlation of (R=0.55, p=0.002). The Cox-regression analysis reveals that 4D flow V Peak significantly predicts AV intervention (HR=2.51, p<0.01), while CWD V Peak (HR=0.54, p=0.76) shows no significant association; overall model fit is significant (χ²=9.5, p=0.02). Conclusion 4D flow CMR-derived V Peak assessment is superior to echocardiographic CWD assessment for predicting timing of AV intervention. Trial registration number NCT05114785 .
No takes yet. Share an insight, caveat, or question.
Grafton‐Clarke et al. (2025) conducted an observational in Aortic stenosis (n=30). 4D flow cardiovascular MRI vs. Transthoracic echocardiography was evaluated on Predicting aortic valve intervention (HR 2.51, p=<0.01).