Motivation Secondary structure prediction accuracy (SSPA) in the QuanTest benchmark can be used to measure accuracy of a multiple sequence alignment. SSPA correlates well with the sum-of-pairs score, if the results are averaged over many alignments but not on an alignment-by-alignment basis. This is due to a sub-optimal selection of reference and non-reference sequences in QuanTest. Results We develop an improved strategy for selecting reference and non-reference sequences for a new benchmark, QuanTest2. In QuanTest2, SSPA and SP correlate better on an alignment-by-alignment basis than in QuanTest. Guide-trees for QuanTest2 are more balanced with respect to reference sequences than in QuanTest. QuanTest2 scores correlate well with other well-established benchmarks. Availability and implementation QuanTest2 is available at http://bioinf.ucd.ie/quantest2.tar, comprises of reference and non-reference sequence sets and a scoring script. Supplementary information Supplementary data are available at Bioinformatics online
No takes yet. Share an insight, caveat, or question.
Sievers et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: