Key result
Variability in distension rate of the common carotid artery is a more accurate predictor of R-R interval variability than variability in systolic arterial finger pressure.
Why the study?
Does non-invasive assessment of carotid artery diameter variations predict heart rate variability more accurately than peripheral arterial finger pressure?
Observational
Does non-invasive assessment of carotid artery diameter variations predict heart rate variability more accurately than peripheral arterial finger pressure?
Carotid artery distension rate variability measured via ultrasound is superior to peripheral arterial finger pressure for predicting heart rate variability and assessing baroreceptor sensitivity.
May support carotid ultrasound over finger pressure for baroreflex assessment; hypothesis-generating and requires prospective validation.
OBJECTIVE AND DESIGN: Recently we developed a non-invasive ultrasound technique, enabling the determination of end-diastolic diameter and distension (increase in diameter during cardiac cycle) over a long time period. Using this technique we test the hypothesis that low-frequency variations derived from non-invasively determined common carotid artery diameter signals are superior to those derived from non-invasively determined arterial pressure to predict heart rate variability, a method used to assess baroreceptor sensitivity. Moreover, we investigate whether the reduced baroreflex sensitivity in the elderly persists after eliminating the influence of the stiffness of the vessel wall and can be attributed to an impairment of the neural baroreflex pathways. RESULTS: The main finding of the present study is that variability in distension rate, i.e. increase in diameter during the cardiac cycle per systolic time interval, of the common carotid artery is a considerably more accurate predictor of R-R interval variability than variability in systolic arterial finger pressure. Moreover, distension rate variability is a more accurate predictor of R-R interval variability than distension and diameter variability. The reduced baroreflex sensitivity in the elderly persists in spite of the elimination of the influence of the stiffness of the vessel wall. CONCLUSIONS: We conclude that: (1) in the evaluation of baroreceptor sensitivity the assessment of variations in parameters derived from carotid arterial diameter is superior to the assessment of parameters derived from peripheral arterial finger pressure; and (2) conduction by the neural baroreflex pathways deteriorates with age.
No takes yet. Share an insight, caveat, or question.
Kornet et al. (2002) conducted an observational in Cardiac baroreceptor sensitivity assessment. Carotid arterial diameter variations (distension rate) vs. Systolic arterial finger pressure variations was evaluated on Prediction of R-R interval variability. Variability in distension rate of the common carotid artery is a more accurate predictor of R-R interval variability than variability in systolic arterial finger pressure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: