Key result
Corrected sinus node recovery time > 550 ms predicts atrial fibrillation recurrence after ablation.
Why the study?
AF and sinus node dysfunction share pathophysiological mechanisms, and whether corrected sinus node recovery time predicts AF recurrence after ablation was unknown.
Does corrected sinus node recovery time (CSNRT) predict atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation undergoing radiofrequency catheter ablation?
Cohort (n=159)
Does corrected sinus node recovery time (CSNRT) predict atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation undergoing radiofrequency catheter ablation?
Corrected sinus node recovery time (CSNRT) > 550 ms and larger left atrial volume index are independent predictors of AF recurrence following radiofrequency ablation for paroxysmal AF.
Answers are grounded in this paper and cite their sources.
May aid post-ablation risk stratification in paroxysmal AF; hypothesis-generating and requires prospective validation before clinical use.
Objective Atrial fibrillation (AF) and sinus node dysfunction (SND) have common underlying pathophysiological mechanisms. As an index of SND, corrected sinus node recovery time (CSNRT) may also reflect atrial function. The aim of the present study was to determine whether CSNRT predicts AF recurrence in patients undergoing AF ablation. Methods Consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent radiofrequency catheter ablation between January 2017 and December 2018 were enrolled. Clinical data, CSNRT, and other electrophysiology indices were collected and analysed between patients with or without AF recurrence. Results A total of 159 patients with PAF who underwent the same radiofrequency catheter ablation procedure were enrolled, including 25 patients with SND. During the one-year follow-up period, 22 patients experienced AF recurrence. Patients with recurrence had a significantly longer CSNRT and a larger left atrial volume index (LAVI) than patients without AF recurrence. SND (CSNRT > 550 ms) and a larger LAVI were independently associated with AF recurrence after ablation. A statistically significant CSNRT cut-off value of 550 ms predicted AF recurrence with 73% sensitivity and 85% specificity. Conclusion CSNRT and LAVI are independent predictors of PAF recurrence following ablation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2021) conducted a cohort in Paroxysmal atrial fibrillation (n=159). Corrected sinus node recovery time (CSNRT) was evaluated on Atrial fibrillation recurrence. A corrected sinus node recovery time > 550 ms independently predicted atrial fibrillation recurrence after ablation with 73% sensitivity and 85% specificity.
Synapse has enriched 10 related papers. Consider them for comparative context: