Key result
Situs inversus totalis shows normal LV pump function despite abnormal myocardial torsion and shear patterns.
Why the study?
How do myocardial deformation patterns, specifically circumferential-radial shear, differ between normal subjects and those with situs inversus totalis?
Observational (n=18)
How do myocardial deformation patterns, specifically circumferential-radial shear, differ between normal subjects and those with situs inversus totalis?
Normal left ventricular pump function is maintained in situs inversus totalis despite abnormal torsional and shear patterns caused by partial mirroring of myocardial structure.
Highlights resilience of LV function despite mirrored architecture; leaves open role of shear patterns in other structural cardiomyopathies.
Situs inversus totalis (SIT) is characterized by complete mirroring of gross cardiac anatomy and position combined with an incompletely mirrored myofiber arrangement, being normal at the apex but inverted at the base of the left ventricle (LV). This study relates myocardial structure to mechanical function by analyzing and comparing myocardial deformation patterns of normal and SIT subjects, focusing especially on circumferential-radial shear. In nine control and nine SIT normotensive human subjects, myocardial deformation was assessed from magnetic resonance tagging (MRT) image sequences of five LV short-axis slices. During ejection, no significant difference in either circumferential shortening (εcc) or its axial gradient (Δεcc) is found between corresponding LV levels in control and SIT hearts. Circumferential-radial shear (εcr) has a clear linear trend from apex-to-base in controls, while in SIT it hovers close to zero at all levels. Torsion as well as axial change in εcr (Δεcr) is as in controls in apical sections of SIT hearts but deviates significantly towards the base, changing sign close to the LV equator. Interindividual variability in torsion and Δεcr values is higher in SIT than in controls. Apex-to-base trends of torsion and Δεcr in SIT, changing sign near the LV equator, further substantiate a structural transition in myofiber arrangement close to the LV equator itself. Invariance of εcc and Δεcc patterns between controls and SIT subjects shows that normal LV pump function is achieved in SIT despite partial mirroring of myocardial structure leading to torsional and shear patterns that are far from normality.
No takes yet. Share an insight, caveat, or question.
Rossi et al. (2014) conducted an observational in Situs inversus totalis (n=18). Magnetic resonance tagging (MRT) vs. Normal controls was evaluated on Myocardial deformation patterns (circumferential-radial shear, torsion, circumferential shortening). In 9 subjects with situs inversus totalis and 9 controls, normal LV pump function was achieved despite partial mirroring of myocardial structure leading to abnormal torsional and shear patterns.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: