Key result
Conduction system and multipoint pacing offer potential CRT alternatives for BiV pacing non-responders.
Why the study?
Non-response continues to plague classical biventricular pacing in dyssynchronous heart failure with reduced ejection fraction, warranting evaluation of alternative CRT modalities.
Do alternative pacing modalities improve response in heart failure patients who are non-responders to classical biventricular pacing?
Do alternative pacing modalities improve response in heart failure patients who are non-responders to classical biventricular pacing?
This review outlines alternative pacing strategies, such as conduction system pacing and multipoint pacing, to improve outcomes in heart failure patients who do not respond to traditional biventricular pacing.
Cardiac resynchronization therapy (CRT) is a cornerstone in the treatment of dyssynchronous heart failure with reduced ejection fraction. However, the phenomenon of non-response has plagued CRT since its initial application. Notwithstanding issues such as failure to capture the left ventricle, lower-than-required pacing delivery percent, and failure to optimize atrioventricular and interventricular delays, there are patients who fail to exhibit an adequate response to CRT in its classical biventricular pacing (BiVP) form. Several modalities have been proposed as a means to remedy this issue, including pacing the conduction system itself-His or left bundle branch pacing, allowing for intrinsic conduction in some myocardial segments, pacing the left ventricle from multiple points in the coronary sinus (multipoint pacing), or even combining the above (e.g., His/left bundle pacing and BiVP leading to His/left bundle-optimized CRT). In the present review, we present recent evidence for the advantages and disadvantages of each modality and attempt to formulate a pathophysiology and simulation-based strategy to determine the best way forward for delivering CRT in non-responders to BiVP.
No takes yet. Share an insight, caveat, or question.
Antoniou et al. (2025) conducted a review in Dyssynchronous heart failure with reduced ejection fraction non-responsive to biventricular pacing. Multipoint pacing and conduction system pacing (His/left bundle branch) vs. Classical biventricular pacing was evaluated. Alternative pacing modalities, including multipoint and conduction system pacing, offer potential strategies for delivering cardiac resynchronization therapy in non-responders to biventricular pacing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: