Key result
Low lead II f-wave and high V1 rate identify long-standing persistent AF with ~6-fold higher odds.
Why the study?
The study investigated whether surface ECG f-wave amplitude, irregularity, and dominant rate in leads II, aVL, and V1 could discriminate long-standing persistent AF from non-long-standing persistent AF.
Do surface ECG f-wave characteristics (amplitude, irregularity, and dominant rate) discriminate long-standing persistent AF from other types of AF?
Observational (n=224)
Single-blind
Do surface ECG f-wave characteristics (amplitude, irregularity, and dominant rate) discriminate long-standing persistent AF from other types of AF?
We characterized the f-waves in atrial fibrillation (AF) in the surface ECG by quantifying the amplitude, irregularity, and dominant rate of the f-waves in leads II, aVL, and V 1 , and investigated whether those parameters of the f-waves could discriminate long-standing persistent AF (LPeAF) from non-LPeAF. A total of 224 AF patients were enrolled: 112 with PAF (87 males), 48 with PeAF (38 males), and 64 with LPeAF (47 males). The f-waves in surface ECG leads V 1 , aVL, and II, which reflect well electrical activity in the right atrium (RA), the left atrium (LA), and both atria, respectively, were analyzed. The f-waves for LPeAF had lower amplitudes in II and aVL, increased irregularity and a higher dominant rate in II and V 1 compared to PAF and PeAF (all p < 0.02). In a multivariate analysis, a low amplitude in lead II (<34.6 uV) and high dominant rate in lead V 1 (≧390/min) (p < 0.00 1 ) independently discriminated LPeAF from the other AF types. The f-waves combined with both a low amplitude in lead II and high dominant rate in lead V 1 were significantly associated with LPeAF (OR 6.27, p < 0.001). Characteristics of the f-waves on the surface ECG could discriminate LPeAF from other types of AF.
No takes yet. Share an insight, caveat, or question.
Park et al. (2019) conducted an observational in Atrial fibrillation (n=224). Surface ECG f-wave characteristics (low amplitude in lead II and high dominant rate in lead V1) vs. Other types of AF (paroxysmal and persistent) was evaluated on Discrimination of long-standing persistent AF (LPeAF) (OR 6.269, 95% CI 2.958-13.285, p=<0.001). The combination of a low f-wave amplitude in lead II and a high dominant rate in lead V1 on surface ECG significantly discriminated long-standing persistent atrial fibrillation from other AF types (OR 6.27).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: