Key result
Wearable sensor impact data predicts ~24% of serum creatinine changes during off-road racing.
Why the study?
This study was conducted to explore the potential use of wearable sensors to assess cumulative mechanical kidney trauma during endurance off-road running.
Does impact data from wearable sensors predict changes in kidney function markers in endurance off-road runners?
Observational (n=18)
Does impact data from wearable sensors predict changes in kidney function markers in endurance off-road runners?
Wearable sensors measuring mechanical impacts during endurance running can partially predict acute changes in kidney function markers.
Impact data from wearables may flag kidney stress in endurance runners; hypothesis-generating and should not yet change practice.
(1) Background: This study aimed to explore wearable sensors′ potential use to assess cumulative mechanical kidney trauma during endurance off-road running. (2) Methods: 18 participants (38.78 ± 10.38 years, 73.24 ± 12.6 kg, 172.17 ± 9.48 cm) ran 36 k off-road race wearing a Magnetic, Angular Rate and Gravity (MARG) sensor attached to their lower back. Impacts in g forces were recorded throughout the race using the MARG sensor. Two blood samples were collected immediately pre- and post-race: serum creatinine (sCr) and albumin (sALB). (3) Results: Sixteen impact variables were grouped using principal component analysis in four different principal components (PC) that explained 90% of the total variance. The 4th PC predicted 24% of the percentage of change (∆%) of sCr and the 3rd PC predicted the ∆% of sALB by 23%. There were pre- and post-race large changes in sCr and sALB (p ≤ 0.01) and 33% of participants met acute kidney injury diagnosis criteria. (4) Conclusions: The data related to impacts could better explain the cumulative mechanical kidney trauma during mountain running, opening a new range of possibilities using technology to better understand how the number and magnitude of the g-forces involved in off-road running could potentially affect kidney function.
No takes yet. Share an insight, caveat, or question.
Rojas‐Valverde et al. (2020) conducted an observational in Cumulative mechanical kidney trauma in endurance off-road running (n=18). Magnetic, Angular Rate and Gravity (MARG) sensor was evaluated on Percentage of change (∆%) of serum creatinine (sCr) and albumin (sALB) (p=≤0.01). Wearable sensor impact data predicted 24% of the change in serum creatinine and 23% of the change in serum albumin during a 36 km off-road race, with 33% of participants meeting AKI criteria.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: