Key result
Echocardiography provided cardiac anatomical measurements comparable to dual-source computed tomography in normal beagles, though it significantly underestimated interventricular septal and left ventricular posterior wall thickness in end diastole.
Why the study?
Does echocardiography provide accurate cardiac anatomical measurements compared to dual-source computed tomography in normal beagles?
Observational (n=7)
No
Does echocardiography provide accurate cardiac anatomical measurements compared to dual-source computed tomography in normal beagles?
Echocardiography is generally as accurate and reliable as dual-source computed tomography for cardiac anatomical assessment in a beagle model, despite minor differences in specific wall thickness measurements.
The aim of this study was to verify the accuracy of echocardiography by dual-source computed tomography (DSCT). Seven normal beagles underwent DSCT and echocardiography. Echocardiographic measurements were obtained according to the American Society of Echocardiography guidelines. The DSCT images were reconstructed onto the same echocardiographic image plane by using a reconstruction program, and then anatomical measurements were obtained. Nonparametric analysis was used for verifying the significance of each of the measured parameters. The anatomical measurements obtained using echocardiography and DSCT were not significant (P>0.05), and the difference between the measurements obtained using both the methods were within 95% confidence intervals except those for interventricular septal thickness and left ventricular posterior wall thickness in end diastole. The reasons for these differences were considered to be the adjacent structures such as papillary muscles or chordae tendineae that may have influenced the echocardiographic findings, lower far-field image quality of echocardiography, low test-retest reproducibility of echocardiography, high-quality images of DSCT minimizing the motion artifact and the retrospective ECG gating technique of DSCT that offered an adequate timing decision for the systolic and diastolic phase during cardiac movement. Although there were differences in the measurements of interventricular septal thickness and left ventricular posterior wall thickness in end diastole obtained using echocardiography and DSCT, we could conclude that echocardiographic measurement is as accurate and reliable as DSCT for cardiac anatomical assessment.
No takes yet. Share an insight, caveat, or question.
Park et al. (2012) conducted an observational in Healthy (normal cardiac anatomy) (n=7). Echocardiography vs. Dual-source computed tomography (DSCT) was evaluated on Interventricular septal thickness in end diastole (IVSd) in mm (p=<0.05). Echocardiography provided cardiac anatomical measurements comparable to dual-source computed tomography in normal beagles, though it significantly underestimated interventricular septal and left ventricular posterior wall thickness in end diastole.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on EchocardiographyMore from Journal of Veterinary Medical Science