Key result
Candidemia in CIED patients is linked to confirmed device infections and ~74% 90-day mortality.
Why the study?
Data regarding candidemia and the risk of CIED infection are limited compared to bloodstream infections caused by various bacteria.
What is the incidence of CIED infection and mortality in patients with candidemia and a CIED?
Cohort (n=23)
No
What is the incidence of CIED infection and mortality in patients with candidemia and a CIED?
Candidemia in patients with CIEDs is associated with high 90-day mortality (73.9%) and diagnostic uncertainty regarding device infection, complicating management decisions despite current guidelines.
Diagnostic uncertainty with high mortality in candidemia and CIED warrants cautious management; leaves open optimal device strategies.
Background In contrast to bloodstream infection due to a variety of bacteria in patients with cardiovascular implantable electronic devices (CIED), there are limited data regarding candidemia and risk of CIED infection. Methods All patients with candidemia and a CIED at Mayo Clinic Rochester between 2012 and 2019 were reviewed. Cardiovascular implantable electronic device infection was defined by (1) clinical signs of pocket site infection or (2) echocardiographic evidence of lead vegetations. Results A total of 23 patients with candidemia had underlying CIED; 9 (39.1%) cases were community onset. None of the patients had pocket site infection. The duration between CIED placement and candidemia was prolonged (median 3.5 years; interquartile range, 2.0–6.5). Only 7 (30.4%) patients underwent transesophageal echocardiography and 2 of 7 (28.6%) had lead masses. Only the 2 patients with lead masses underwent CIED extraction, but device cultures were negative for Candida species. Two (33.3%) of 6 other patients who were managed as candidemia without device infection subsequently developed relapsing candidemia. Cardiovascular implantable electronic device removal was done in both patients and device cultures grew Candida species. Although 17.4% of patients were ultimately confirmed to have CIED infection, CIED infection status was undefined in 52.2%. Overall, 17 (73.9%) patients died within 90 days of diagnosis of candidemia. Conclusions Although current international guidelines recommend CIED removal in patients with candidemia, the optimal management strategy remains undefined. This is problematic because candidemia alone is associated with increased morbidity and mortality as seen in this cohort. Moreover, inappropriate device removal or retention can both result in increased patient morbidity and mortality.
No takes yet. Share an insight, caveat, or question.
Chesdachai et al. (2023) conducted a cohort in Candidemia with cardiovascular implantable electronic devices (n=23). Candidemia in patients with cardiovascular implantable electronic devices was associated with a 17.4% confirmed device infection rate and a 73.9% 90-day mortality rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: