Key result
Non-invasive STE parameters strongly correlate with invasive atrial electrophysiological properties including conduction block.
Why the study?
Non-invasive assessment of arrhythmogenic substrates underlying persistent AF could potentially provide patient-tailored ablation therapy, but it is unknown which STE-derived measurements correlate best with invasive electrophysiological properties.
Does Speckle Tracking Echocardiography correlate with invasive electrophysiological properties in adult patients undergoing cardiac surgery?
Observational (n=19)
Does Speckle Tracking Echocardiography correlate with invasive electrophysiological properties in adult patients undergoing cardiac surgery?
Effect estimate: ρ = 0.68
p-value: p=<0.001
Speckle Tracking Echocardiography timing and slope parameters correlate strongly with invasive atrial electrophysiological properties, suggesting its potential as a non-invasive tool to detect arrhythmogenic substrates for patient-tailored ablation.
May support STE as non-invasive correlate of atrial conduction; leaves open utility for guiding ablation.
BACKGROUND: Non-invasive assessment of arrhythmogenic substrates underlying persistent atrial fibrillation (AF) could potentially provide patient-tailored ablation therapy. Speckle Tracking Echocardiography (STE) is an imaging modality, which can be used to assess atrial biomechanical function. As biomechanical dysfunction is driven by electrical dysfunction, STE may serve as a diagnostic tool to detect AF-related arrhythmogenic substrates. PURPOSE: To investigate which non-invasive STE-derived measurements correlate best with invasively determined electrophysiological properties as a first step towards developing a novel, non-invasive diagnostic tool. METHODS: Intraoperative epicardial mapping during sinus rhythm was performed in adult patients (n = 19, mean age: 63 ± 13 years) undergoing cardiac surgery. Potential voltages, potential morphology, conduction velocity (CV), conduction block (CB: ≥12 ms) and uninterrupted lines of conduction delay (CD: ≥7 ms) and CB (CDCB) were quantified. Atrial end-diastolic reservoir and contractile strain values were used to calculate area under the curve, and the slopes of both the reservoir and contractile phases. RESULTS: Steeper LA reservoir strain slopes were associated with more CDCB, greater CV variation and lower overall CV around the pulmonary veins (ρ = 0.55, p < 0.001; ρ = 0.64, p = 0.004; ρ = -0.55, p = 0.019). A larger right atrial volume indexed correlated with more CDCB, fractionated potentials and reduced CV on Bachmann's Bundle (ρ = 0.64, p = 0.008; ρ = 0.52, p = 0.037; ρ = -0.61, p = 0.011). Right atrial end-systolic time strongly correlated with CB, low-voltage area's and fractionated potentials on Bachmann's Bundle (ρ = 0.68, p < 0.001; ρ = -0.63, p = 0.009; ρ = 0.53, p = 0.020). CONCLUSION: STE timing and slope parameters correlated most strongly with atrial electrophysiological properties, supporting their potential as non-invasive markers for arrhythmogenic substrates and patient-tailored ablation therapy.
No takes yet. Share an insight, caveat, or question.
Linderhof et al. (2026) conducted an observational in persistent atrial fibrillation (n=19). Speckle Tracking Echocardiography (STE) vs. Intraoperative epicardial mapping was evaluated on Correlation between non-invasive STE-derived measurements and invasively determined electrophysiological properties (ρ = 0.68, p=<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: