Key result
A physiologically realistic computer simulator of left ventricle myocardium images showed high correlation with actual deformations in patients with acute myocardial infarction.
The proposed magnetic resonance software simulator accurately models myocardial deformation and ejection fraction, providing a testbed for evaluating myocardial motion tracking methods.
Enables safer testing of myocardial motion tracking methods in AMI; extends computational simulator validation for research applications.
This paper proposes a methodology to design a physiologically realistic computer simulator of images of the left ventricle myocardium based on a patient-specific biomechanical model. The simulator takes a magnetic resonance image of a given patient at end diastole, uses a manual segmentation of that image to model the geometry of the myocardium and sets the parameters of the constitutive model used for biomechanical simulation according to a regional labeling of the contractility of the myocardium for that patient. The simulated deformations are used to warp the magnetic resonance dataset throughout the cardiac cycle to generate different image modalities. The simulator is validated by quantifying its ability to model actual deformations in a set of patients affected by an acute myocardial infarction. Specifically a high correlation has been encountered between the ejection fraction derived from the simulated end systolic deformation of the myocardium and the myocardium segmented from actual data. Additionally, most of the parameters that describe the simulated deformation compare well with reported values. Overall, the simulator is intended as a testbed for extensive comparisons of myocardial motion tracking methods due to its ability to relate the impaired myocardial function with the associated ventricular remodeling, a novel contribution in the literature of cardiac image simulators.
No takes yet. Share an insight, caveat, or question.
Cordero‐Grande et al. (2013) studied Acute myocardial infarction. Magnetic resonance software simulator based on a patient-specific biomechanical model vs. Actual deformations from segmented actual data was evaluated on Correlation between ejection fraction derived from simulated end systolic deformation and actual data. A physiologically realistic computer simulator of left ventricle myocardium images showed high correlation with actual deformations in patients with acute myocardial infarction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: