We present a new detection scheme for acousto-optic tomography based on pulsed-wave ultrasound and illumination combined with heterodyne parallel speckle detection. This setup can perform tomographies inside several-centimeter-thick scattering samples. Test experiments confirm the suitability of this method for performing tomographies inside various types of optically scattering media, including liquids.