Why the study?
The use of an automated annotation algorithm based on unipolar -dV/dTmax for local activation timing in ablation of outflow tract VPCs remains controversial.
Does automated annotation based on unipolar -dV/dTmax differ spatially from manual bipolar annotation in identifying earliest activation sites in patients with outflow tract ventricular premature contractions?
Does automated annotation based on unipolar -dV/dTmax differ spatially from manual bipolar annotation in identifying earliest activation sites in patients with outflow tract ventricular premature contractions?
Automated unipolar mapping significantly diverges from manual bipolar mapping in identifying the earliest activation site for VPCs originating from the aortic sinus cusps, highlighting the need for careful interpretation during ablation.
Larger EAS divergence in ASC-origin VPCs supports cautious automated unipolar use; leaves open impact on ablation success.
BACKGROUND: The use of an automated annotation algorithm based on the maximal negative derivative of the unipolar potential (-dV/dTmax) for local activation timing in the ablation of outflow tract (OT) ventricular premature contractions (VPCs) remains controversial. OBJECTIVE: To investigate the spatial differences in the earliest activation sites (EASs) of OT-VPCs identified by an automated annotation based on unipolar -dV/dTmax versus manual annotation using local bipolar potentials. METHODS: Seventy-nine patients with frequent OT-VPCs who underwent successful ablation were included. VPCs originated from the right ventricular OT (RVOT) free wall (n = 10), RVOT septum (n = 25), aortomitral continuity (AMC) (n = 19), and aortic sinus cusps (ASCs) (n = 25). The spatial distance between EASs identified by the two annotation methods was analyzed. RESULTS: The spatial distance between EASs was significantly larger in ASC-origin VPCs compared to non-ASC-origin VPCs (median: 11.9 mm [IQR: 7.9-14.9] vs. 1.2 mm [IQR: 0.0-3.3], p < 0.001). Among non-ASC-origin VPCs, the spatial difference was smallest in VPCs from the RVOT free wall (median: 0 mm) and larger in those from the RVOT septum (median: 1.6 mm) and AMC (median: 2.2 mm). CONCLUSION: The spatial discordance of EAS between unipolar and bipolar mapping varies by the VPC origin site. The discrepancy is particularly pronounced in ASC-origin VPCs, emphasizing the need for careful interpretation of automated annotation algorithms to ensure accurate localization and effective ablation.
No takes yet. Share an insight, caveat, or question.
An et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: