Why the study?
Whether patients undergoing an LVAD bridge-to-recovery protocol can achieve cardiac and physical functional capacities equivalent to those of healthy controls needed evaluation.
Does an LVAD bridge-to-recovery protocol allow patients with advanced heart failure to achieve cardiac and physical functional capacities equivalent to healthy controls?
Cross-Sectional (n=155)
Does an LVAD bridge-to-recovery protocol allow patients with advanced heart failure to achieve cardiac and physical functional capacities equivalent to healthy controls?
Answers are grounded in this paper and cite their sources.
A substantial proportion of advanced heart failure patients who undergo LVAD explantation after a bridge-to-recovery protocol can achieve peak exercise cardiac power output (38%) and peak oxygen consumption (69%) within the ranges of healthy controls.
Left ventricular assist devices (LVADs) have been used as an effective therapeutic option in patients with advanced heart failure, either as a bridge to transplantation, as destination therapy, or in some patients, as a bridge to recovery. This study evaluated whether patients undergoing an LVAD bridge-to-recovery protocol can achieve cardiac and physical functional capacities equivalent to those of healthy controls. Fifty-eight male patients—18 implanted with a continuous-flow LVAD, 16 patients with LVAD explanted (recovered patients), and 24 heart transplant candidates (HTx)—and 97 healthy controls performed a maximal graded cardiopulmonary exercise test with continuous measurements of respiratory gas exchange and noninvasive (rebreathing) hemodynamic data. Cardiac function was represented by peak exercise cardiac power output (mean arterial blood pressure × cardiac output) and functional capacity by peak exercise O2 consumption. All patients demonstrated a significant exertional effort as demonstrated with the mean peak exercise respiratory exchange ratio >1.10. Peak exercise cardiac power output was significantly higher in healthy controls and explanted LVAD patients compared with other patients (healthy 5.35 ± 0.95 W; explanted 3.45 ± 0.72 W; LVAD implanted 2.37 ± 0.68 W; and HTx 1.31 ± 0.31 W; p < 0.05), as was peak O2 consumption (healthy 36.4 ± 10.3 ml/kg/min; explanted 29.8 ± 5.9 ml/kg/min; implanted 20.5 ± 4.3 ml/kg/min; and HTx 12.0 ± 2.2 ml/kg/min; p < 0.05). In the LVAD explanted group, 38% of the patients achieved peak cardiac power output and 69% achieved peak O2 consumption within the ranges of healthy controls. The authors have shown that a substantial number of patients who recovered sufficiently to allow explantation of their LVAD can even achieve cardiac and physical functional capacities nearly equivalent to those of healthy controls.
No takes yet. Share an insight, caveat, or question.
Jakovljević et al. (2017) conducted a cross-sectional in Advanced heart failure (n=155). LVAD bridge-to-recovery (LVAD explanted) vs. Healthy controls, LVAD implanted patients, and heart transplant candidates was evaluated on Peak exercise cardiac power output and peak exercise O2 consumption (p=<0.05).
Synapse has enriched 10 related papers. Consider them for comparative context: