Why the study?
Posterior wall ablation is commonly added to pulmonary vein isolation during catheter ablation of persistent AF, but comparison between very-high-power short-duration and standard-power ablation index-guided approaches was needed.
Does very-high-power short-duration radiofrequency ablation reduce the recurrence of atrial tachyarrhythmias compared to standard-power ablation in patients with persistent atrial fibrillation?
Does very-high-power short-duration radiofrequency ablation reduce the recurrence of atrial tachyarrhythmias compared to standard-power ablation in patients with persistent atrial fibrillation?
Very-high-power short-duration ablation for persistent atrial fibrillation is faster and may offer superior efficacy compared to standard-power ablation, without increasing major complications.
Background Posterior wall ablation (PWA) is commonly added to pulmonary vein isolation (PVI) during catheter ablation (CA) of persistent atrial fibrillation (AF). Objective The purpose of this study was to compare PVI plus PWA using very-high-power short-duration (vHPSD) vs standard-power (SP) ablation index-guided CA among consecutive patients with persistent AF and to determine the voltage correlation between microbipolar and bipolar mapping in AF. Methods We compared 40 patients undergoing PVI plus PWA using vHPSD to 40 controls receiving PVI plus PWA using SP. The primary efficacy endpoint was recurrence of atrial tachyarrhythmias after a 3-month blanking period. The primary safety outcome was a composite of major complications within 30 days after CA. In the vHPSD group, high-density mapping of the posterior wall was performed using both a multipolar catheter and microelectrodes on the tip of the ablation catheter. Results PVI was more commonly obtained with vHPSD compared to SP ablation (98%vs 75%; P = .007), despite shorter procedural and fluoroscopy times (P <.001). Survival free from recurrent atrial tachyarrhythmias at 18 months was 68% and 47% in the vHPSD and SP groups, respectively (log-rank P = .071), without major adverse events. The vHPSD approach was significantly associated with reduced risk of recurrent AF at multivariable analysis (hazard ratio 0.39; P = .030). Microbipolar voltage cutoffs of 0.71 and 1.69 mV predicted minimum bipolar values of 0.16 and 0.31 mV in AF, respectively, with accuracies of 0.67 and 0.88. Conclusion vHPSD PWA plus PVI may be faster and as safe as SP CA among patients with persistent AF, with a trend for superior efficacy. Adapted voltage cutoffs should be used for identifying atrial low-voltage areas with microbipolar mapping.
No takes yet. Share an insight, caveat, or question.
Compagnucci et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: