There is a need in the field of modular robotics for a low-profile docking face with a wide range of performance. Mechanical self-aligning geometry features for docking faces of modular reconfigurable robot systems can be varied to improve the reliability of connection systems. This paper presents a new two-layer mating face design for robots that are constrained to move in a plane. It has a provably larger area of acceptance than any to date. We present an analysis of both position and orientation misalignments with simulated results over a two parameter design space comparing this connector with two other best-in-class shapes. The results show an average acceptance area increase approximately 88% over gendered mating faces and approximately 138% over non-gendered mating faces.
No takes yet. Share an insight, caveat, or question.
Eckenstein et al. (2012) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: