Data regarding the use of interferon-gamma release assays (IGRAs) for tuberculosis diagnosis are accumulating. We systematically searched PubMed, EMBASE and Cochrane and performed pooled estimates of sensitivity and specificity of QuantiFERON-TB Gold In Tube (QFT-G-IT) and T-SPOT.TB compared to tuberculin skin test (TST). For studies assessing sensitivity, children had to have active tuberculosis. Specificity data were derived from children classified as non-infected. Eleven studies were included in the sensitivity analysis for TST, 10 for QFT-G-IT, and 9 for T-SPOT.TB. Eight studies were included in specificity analysis for TST, 8 for QFT-G-IT, and 7 for T-SPOT.TB. Pooled QFT-G-IT sensitivity was 0.79 (95% CI:0.70-0.89) pooled T-SPOT.TB sensitivity was 0.74 (95% CI:0.59-0.90) and pooled TST sensitivity was 0.82 (95% CI:0.72-0.93). Pooled QFT-G-IT and T-SPOT.TB specificities were 0.95 (95% CI:0.93- 0.97) and 0.96 (95% CI:0.93-1.00), respectively. Pooled TST specificity was significantly lower 0.83 (95% CI:0.74-0.92). IGRA performance in children showed no better sensitivity than TST, but higher specificity.
No takes yet. Share an insight, caveat, or question.
Chiappini et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: