Key result
Applying traditional one-compartment models to voxelwise fractions of tissue overestimates perfusion by 159.6% compared to averaging concentrations for the entire volume of interest.
Traditional one-compartment models overestimate perfusion when applied to fractions of tissue, highlighting the need for careful interpretation of computed values for diagnosis and treatment planning.
Answers are grounded in this paper and cite their sources.
Demands caution interpreting voxelwise perfusion estimates clinically; leaves open validation of volume-averaged models.
One-compartment models are widely used to quantify hemodynamic parameters such as perfusion, blood volume and mean transit time. These parameters are routinely used for clinical diagnosis and monitoring of disease development and are thus of high relevance. However, it is known that common estimation techniques are discretization dependent and values can be erroneous. In this paper we present a new model that enables systematic quantification of discretization errors. Specifically, we introduce a continuous flow model for tracer propagation within the capillary tissue, used to evaluate state-of-the-art one-compartment models. We demonstrate that one-compartment models are capable of recovering perfusion accurately when applied to only one compartment, i.e. the whole region of interest. However, substantial overestimation of perfusion occurs when applied to fractions of a compartment. We further provide values of the estimated overestimation for various discretization levels, and also show that overestimation can be observed in real-life applications. Common practice of using compartment models for fractions of tissue violates model assumptions and careful interpretation is needed when using the computed values for diagnosis and treatment planning.
No takes yet. Share an insight, caveat, or question.
Hanson et al. (2018) studied Suspicion of stroke (perfusion measurement) (n=1). Voxelwise one-compartment model perfusion estimation (bSVD) vs. Entire brain region one-compartment model perfusion estimation was evaluated on Reconstructed perfusion (ml/min/100ml) (159.60% relative error). Applying traditional one-compartment models to voxelwise fractions of tissue overestimates perfusion by 159.6% compared to averaging concentrations for the entire volume of interest.
Synapse has enriched 10 related papers. Consider them for comparative context: