March 16, 2004Circulation354 citationsOpen Access

Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation System

View Full Paper
SESabine ErnstFOFeifan OuyangCLChristian Linder

Key Result

Remote catheter ablation using the Niobe magnetic navigation system successfully achieved slow pathway ablation or modulation in all 42 patients with AVNRT, with no complications.

Study Design

Type

Observational (n=42)

Structured PICO

Does remote catheter ablation using a magnetic navigation system achieve successful ablation in patients with AVNRT?

P
Population
42 patients (32 female; mean age, 55+/-15 years) undergoing ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventricular nodal reentrant tachycardia (AVNRT)
I
Intervention
Remote catheter ablation using the magnetic navigation system Niobe (Stereotaxis, Inc) with a remote-controlled 4-mm, solid-tip, magnetic navigation-enabled catheter
O
Outcome
Procedural success (slow pathway ablation or modulation)

The Niobe magnetic navigation system successfully enabled completely remote-controlled mapping and ablation in patients with AVNRT without complications.

Abstract

BACKGROUND: Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient's side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. METHODS AND RESULTS: A total of 42 patients (32 female; mean age, 55+/-15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventricular nodal reentrant tachycardia (AVNRT) with the use of the magnetic navigation system Niobe (Stereotaxis, Inc). It consists of 2 computer-controlled permanent magnets located on opposite sides of the patient, which create a steerable external magnetic field (0.08 T). A small magnet embedded in the catheter tip causes the catheter to align and to be steered by the external magnetic field. A motor drive advances or retracts the catheter, enabling complete remote navigation. Radiofrequency current was applied with the use of a remote-controlled 4-mm, solid-tip, magnetic navigation-enabled catheter (55 degrees C, maximum 40 W, 60 seconds) in all patients. The investigators, who were situated in the control room, performed the ablation using a mean of 7.2+/-4.7 radiofrequency current applications (mean fluoroscopy time, 8.9+/-6.2 minutes; procedure duration, 145+/-43 minutes). Slow pathway ablation was achieved in 15 patients, whereas slow pathway modulation was the end point in the remaining patients. There were no complications. CONCLUSIONS: The Niobe magnetic navigation system is a new platform technology allowing remote-controlled navigation of an ablation catheter. In conjunction with a motor drive unit, this system was used successfully to perform completely remote-controlled mapping and ablation in patients with AVNRT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ernst et al. (2004) conducted an observational in Atrioventricular nodal reentrant tachycardia (AVNRT) (n=42). Remote catheter ablation using the magnetic navigation system Niobe was evaluated on Slow pathway ablation or modulation. Remote catheter ablation using the Niobe magnetic navigation system successfully achieved slow pathway ablation or modulation in all 42 patients with AVNRT, with no complications.