Key result
Intermittent hypoxia attenuated arterial baroreflex function and elevated mean blood pressure by 11 mmHg in rats, mediated by reactive oxygen species-dependent upregulation of endothelin-1 signaling.
Why the study?
Does intermittent hypoxia attenuate arterial baroreflex function in adult male rats?
Does intermittent hypoxia attenuate arterial baroreflex function in adult male rats?
p-value: p=<0.01
Intermittent hypoxia attenuates arterial baroreflex function via ROS-dependent upregulation of ET-1 signaling in the carotid sinus region.
The objectives of the present study were to examine the effects of intermittent hypoxia (IH) on arterial baroreflex function and assess the underlying mechanism(s). Experiments were performed on adult male rats treated with 14 days of IH (15 s of hypoxia, 5 min of normoxia; 8 h/day) or normoxia (control). Arterial blood pressures were elevated in IH-treated rats, and this effect was associated with attenuated heart rate and splanchnic sympathetic nerve responses to arterial baroreflex activation. In IH-treated rats, carotid baroreceptor responses to elevated sinus pressures were attenuated. Endothelin-1 (ET-1) levels were elevated in the carotid sinus region of IH-treated rats, and this effect was associated with increased endothelin converting enzyme (ECE) activity, which generates biologically active ET-1. ET(A) receptor antagonist prevented the effects of IH on carotid baroreceptor activity. In IH-treated rats, reactive oxygen species (ROS) levels were elevated in the carotid sinus region, and antioxidant treatment prevented the effects of IH on ET-1 levels, ECE activity, carotid baroreceptor activity, and baroreflex function. These results demonstrate that 1) IH attenuates arterial baroreflex function, which is in part due to reduced carotid baroreceptor responses to elevated carotid sinus pressure, and 2) IH-induced carotid baroreceptor dysfunction involves reactive oxygen species-dependent upregulation of ET-1 signaling in the carotid sinus region.
No takes yet. Share an insight, caveat, or question.
Peng et al. (2011) studied Intermittent hypoxia. Intermittent hypoxia vs. Normoxia was evaluated on Mean blood pressure elevation (mmHg) (p=<0.01). Intermittent hypoxia attenuated arterial baroreflex function and elevated mean blood pressure by 11 mmHg in rats, mediated by reactive oxygen species-dependent upregulation of endothelin-1 signaling.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: