Key result
Mindray hs-cTnI assay yields ~95% sensitivity for diagnosing MI using 0- and 2-hour serial testing.
Why the study?
To examine the 0- and 2-h diagnostic performance of the Mindray hs-cTnI assay using two predefined sex-specific 99th percentile upper reference limits in patients with normal electrocardiograms to aid in the diagnosis of MI.
Does the Mindray CL1200i hs-cTnI assay provide accurate diagnostic performance compared to the Abbott Alinity assay for diagnosing acute myocardial infarction in emergency department patients?
Observational (n=1,556)
Does the Mindray CL1200i hs-cTnI assay provide accurate diagnostic performance compared to the Abbott Alinity assay for diagnosing acute myocardial infarction in emergency department patients?
The Mindray CL1200i hs-cTnI assay provides excellent diagnostic performance for acute myocardial infarction using a 0/2-hour serial testing algorithm with sex-specific thresholds.
Supports Mindray hs-cTnI 0/2h testing in ED cohorts; leaves open prospective validation versus Abbott before practice change.
OBJECTIVES: We examined the 0- and 2-h diagnostic performance of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay using two predefined sex-specific 99th percentile upper reference limits (URL) in patients with normal electrocardiograms to aid in the diagnosis of myocardial infarction (MI). METHODS: Consecutive emergency department patients undergoing serial high-sensitivity cardiac troponin I (hs-cTnI) testing on clinical indication were studied in the 'Mindray hs-cTnI Assay Analytical and Clinical Evaluation for the Diagnosis and RIsk Assessment of Myocardial InfarctIon' (MERITnI) trial (NCT05853042). Plasma hs-cTnI testing was performed using Mindray CL1200i (investigational) and Abbott Alinity (clinical) assays. RESULTS: In 1,556 patients (60.7 % male, 43.3 % White, 45.8 % Black, 34.8 % chest pain), 2.7 % had type 1 MI, 2.7 % type 2 MI, and 21.5 % non-MI myocardial injury. At 0 h for all MIs (n=86), using package insert URLs and Universal Sample Bank (USB) URLs, sensitivities were 83.7 and 93.0 %. At 0/2 h for all MIs with package insert and USB URLs, sensitivities were higher with serial testing, at 95.3 and 97.7 %. Negative predictive value (NPVs) were excellent and similar for both URLs, ranging from 98 to 100 %. Substantial hs-cTnI concentration differences were observed between sex and injury types. Alinity hs-cTnI diagnostic observations were similar for both package insert and USB URLs. CONCLUSIONS: The Mindray CL1200i hs-cTnI assay provides the relevant clinical diagnostic information to enable clinicians to deliver cost-effective care for patients to aid in the diagnosis of MI predicated on 0- and 2-h serial testing based on sex-specific 99th percentiles. Novel observations were observed for findings based on different URLs and for females and MI types.
No takes yet. Share an insight, caveat, or question.
Apple et al. (2025) conducted an observational in Acute myocardial infarction (n=1,556). Mindray CL1200i high sensitivity cardiac troponin I assay vs. Abbott Alinity cardiac troponin I assay was evaluated on Sensitivity for all myocardial infarctions at 0 and 2 hours. The Mindray CL1200i hs-cTnI assay demonstrated high sensitivity (95.3-97.7%) and negative predictive value (98-100%) for diagnosing myocardial infarction using 0- and 2-hour serial testing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: