Key result
ICM placement is linked to fewer diagnostic tests and acute syncope events versus pre-implantation.
Why the study?
Despite advances in syncope evaluation strategies and risk stratification, syncope costs remain high due to extensive and repetitive testing.
Does insertable cardiac monitor placement reduce downstream diagnostic testing and syncope recurrence in patients with unexplained syncope?
Observational (n=2,140)
Does insertable cardiac monitor placement reduce downstream diagnostic testing and syncope recurrence in patients with unexplained syncope?
Insertable cardiac monitor placement in patients with unexplained syncope is associated with reduced downstream diagnostic testing and fewer recurrent acute syncope events.
Answers are grounded in this paper and cite their sources.
May reduce diagnostic testing in unexplained syncope; leaves open need for RCTs to confirm outcomes.
Despite advances in syncope evaluation strategies and risk stratification, the high cost of syncope is largely driven by extensive and often repetitive testing. This analysis of a large deidentified US claims database compared the use of diagnostic tests, therapeutic procedures, and the recurrence rate of acute syncope events before and after placement of an insertable cardiac monitor (ICM) in syncope patients. The patients had a minimum of 1 year of continuous enrollment before and 2 years after ICM placement. Among 2140 patients identified, a statistically significant reduction in the use of 14 out of 18 tests was observed during follow-up compared with pre-ICM testing. During the 2-year follow-up, 28.3% of patients underwent cardiac therapeutic interventions after a median of 127 days. Significantly fewer patients experienced acute syncope events during the 1st and 2nd years of ICM follow-up compared with the 1-year pre-ICM period, and the frequency of events per patient also decreased. In conclusion, reductions in diagnostic testing and acute syncope events were observed after ICM placement in a large real-world cohort of unexplained syncope patients. Further studies are needed to prospectively assess the impact of ICM vs. short-term monitoring on patient outcomes and healthcare utilization.
No takes yet. Share an insight, caveat, or question.
Frazier‐Mills et al. (2022) conducted an observational in Syncope (n=2,140). Insertable cardiac monitor (ICM) placement vs. Pre-ICM period (1 year before placement) was evaluated on Use of diagnostic tests, therapeutic procedures, and recurrence rate of acute syncope events. Insertable cardiac monitor placement significantly reduced the use of 14 out of 18 diagnostic tests and acute syncope events compared to the 1-year pre-ICM period.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: