This paper proposes a high frequency injection technique applied for low-speed sensorless control of interior permanent magnet synchronous machines (IPMSM) with a single dc-link current sensor. The three-phase currents, which can be reconstructed by the measurement of a dc-link current sensor, always suffer from the immeasurable regions. The most challenging problem exists in the low modulation region, where no phase current can be measured by the dc-link current sensor, and it is rarely solved without PWM modifications. This paper proposes a six-direction square wave high frequency injection method to extend the voltage vector to the measurable region to achieve the three-phase current reconstruction and saliency-based sensorless control without modifying the space vectors of the pulse width modulation (PWM). In addition, the paper comes up with a modified reconstruction scheme to reduce the reconstruction error and improve the accuracy of the position estimation. This low-speed sensorless strategy using a single dc-link current sensor is implemented in dSpace platform and the performance is evaluated by experiments.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2019) studied this question.