PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 15, 1992Proceedings of the National Academy of Sciences308 citationsOpen Access

Surfactant-induced sealing of electropermeabilized skeletal muscle membranes in vivo.

View Full Paper
RLRaphael C. LeeLRL. Philip RiverFPFusheng Pan

Key Points

  • The aim is to evaluate the effectiveness of surfactants in sealing electropermeabilized skeletal muscle membranes after electrical trauma.
  • Administered poloxamer 188 (P188) intravenously to rat biceps femoris muscle flaps post-electroporation.
  • Measured impedance recovery to assess membrane sealing effectiveness and inflammation reduction.
  • Compared results to neutral dextran and sterile saline controls.
  • P188 restored membrane resistivity to 77% of initial value when given 20 min post-shock.
  • A dose-dependent response was observed when P188 was administered 5 min before shock.
  • Histopathologic studies showed reduced tissue inflammation compared to dextran-treated or control groups.

Abstract

Victims of major electrical trauma frequently suffer extensive skeletal muscle and nerve damage, which is postulated to be principally mediated by electroporation and/or thermally driven cell membrane permeabilization. We have investigated the efficacy of two blood-compatible chemical surfactants for sealing electroporated muscle membranes. In studies using cultured skeletal muscle cells, poloxamer 188 (P188; an 8.4-kDa nonionic surfactant) blocks, and neutral dextran (10.1 kDa) substantially retards, carboxyfluorescein release from electropermeabilized cell membranes. To test whether P188 administered intravenously could have the same therapeutic effect in vivo, the rat biceps femoris muscle flap attached by its arteriovenous pedicle was electropermeabilized until its electrical resistivity dropped to 50% of the initial value. P188 (460 mg/kg) administered intravenously 20 min postshock restored the resistivity to 77% of the initial value. When P188 was administered intravenously 5 min before shock, a dose-dependent impedance recovery rate was observed. Neither neutral dextran (460 mg/kg) nor sterile saline was effective. Histopathologic studies indicated that postshock poloxamer administration reduced tissue inflammation and damage in comparison with dextran-treated or control tissues. Electrophysiologic evidence of membrane damage was not observed in flaps of animals pretreated with poloxamer. These results suggest that it may be possible to seal in vivo tissue membranes injured by electrical, thermal, or other membrane-damaging forces.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lee et al. (1992) studied this question.

synapsesocial.com/papers/6a15310ca2352da3478208bfhttps://doi.org/10.1073/pnas.89.10.4524
Ask AI
Helpful
Bookmark
Share
View Full Paper