This paper presents a model-based control strategy for a power factor correction system that employs a high conversion-ratio DC–DC converter. The proposed system consists of two stages. In the first stage, a full-bridge diode rectifier is connected to the grid through a passive filter to improve the quality of the injected current. Two passive AC input filters, namely L and LCL configurations, are evaluated to analyze their impact on grid current quality and overall system performance. The second stage is a high-step-up DC–DC converter based on the switched-inductor technique, which provides a high voltage conversion ratio. A model-based approach is employed to derive the control design from the averaged system model. The resulting control structure consists of a current tracking loop and a voltage regulation loop. A proportional-resonant controller is used to ensure current tracking and achieve a near-unity power factor, while a proportional-integral controller regulates the output voltage. Experimental validation is carried out using a low-power laboratory-scale prototype to assess the effectiveness of the proposed approach. The results demonstrate adequate current tracking and satisfactory dynamic performance within the tested operating conditions.
Rodríguez-Cortés et al. (Sat,) studied this question.