Key result
Synthetic B-mode ultrasound from finite element simulations yields qualitative displacement similarities to improve reproducibility.
Why the study?
Motion estimation algorithms in B-mode ultrasound are susceptible to inter-vendor variability due to a lack of benchmark motion quantities.
The development of synthetic B-mode ultrasound images from finite element simulations provides a reproducible benchmark for evaluating and improving cardiac motion estimation algorithms.
Provides a preclinical benchmark for cardiac motion estimation algorithms; leaves open human validation before any clinical use.
Brightness mode (B-mode) ultrasound is a common imaging modality in the clinical assessment of several cardiovascular diseases. The utility of ultrasound-based functional indices such as the ejection fraction (EF) and stroke volume (SV) is widely described in diagnosing advanced-stage cardiovascular diseases. Additionally, structural indices obtained through the analysis of cardiac motion have been found to be important in the early-stage assessment of structural heart diseases, such as hypertrophic cardiomyopathy and myocardial infarction. Estimating heterogeneous variations in cardiac motion through B-mode ultrasound imaging is a crucial component of patient care. Despite the benefits of such imaging techniques, motion estimation algorithms are susceptible to variability between vendors due to the lack of benchmark motion quantities. In contrast, finite element (FE) simulations of cardiac biomechanics leverage well-established constitutive models of the myocardium to ensure reproducibility. In this study, we developed a methodology to create synthetic B-mode ultrasound images from FE simulations. The proposed methodology provides a detailed representation of displacements and strains under complex mouse-specific loading protocols of the LV. A comparison between the synthetic images and FE simulations revealed qualitative similarity in displacement patterns, thereby yielding benchmark quantities to improve the reproducibility of motion estimation algorithms. Thus, the study provides a methodology to create an extensive repository of images describing complex motion patterns to facilitate the enhanced reproducibility of cardiac motion analysis.
No takes yet. Share an insight, caveat, or question.
Mukherjee et al. (2024) studied Cardiovascular diseases. Synthetic B-mode ultrasound images from finite element simulations was evaluated on Qualitative similarity in displacement patterns. A methodology to create synthetic B-mode ultrasound images from finite element simulations yielded benchmark quantities with qualitative similarity in displacement patterns to improve reproducibility.