PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 1984IEEE Transactions on Power Apparatus and Systems15 citations

A New Test Method For Determination Of Induction Motor Efficiency

View Full Paper
ADA. Dell’AquilaLSL. SalvatoreMSM. Savino

Key Points

Key points are not available for this paper at this time.

Abstract

A variety of methods of testing induction motors to determine their efficiency is recognized in the world. When tests under load are not made, operating characteristics are universally calculated by the equivalent circuit with a single rotor loop. IEEE Std 112, the test procedure used in the United States, recognizes the use of a single load point in combination with Method F to adjust equivalent circuit parameters in order to determine the expected performance at other loads. This combination of methods is iterative and not simple.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dell’Aquila et al. (1984) studied this question.

synapsesocial.com/papers/6a154af15347fbb1739f8bb7https://doi.org/10.1109/tpas.1984.318299
Ask AI
Helpful
Bookmark
Share
View Full Paper