Key result
Charité Alarm Fatigue Questionnaire demonstrates good construct validity for its two-factor structure among ICU staff.
Why the study?
The study aimed to validate the hypothesized two-scale structure of the 9-item Charité Alarm Fatigue Questionnaire to underpin its construct validity.
Does the Charité Alarm Fatigue Questionnaire (CAFQa) validly measure alarm fatigue in ICU nurses and physicians?
Cross-Sectional (n=1,477)
Yes
Does the Charité Alarm Fatigue Questionnaire (CAFQa) validly measure alarm fatigue in ICU nurses and physicians?
The Charité Alarm Fatigue Questionnaire (CAFQa) is a valid instrument for measuring alarm fatigue among ICU nurses and physicians.
Answers are grounded in this paper and cite their sources.
CAFQa may support alarm fatigue assessment in ICU staff; leaves open links to outcomes or intervention guidance.
Background. The Charité Alarm Fatigue Questionnaire (CAFQa) is a 9-item Questionnaire that aims to standardize how alarm fatigue (AF) in nurses and physicians is measured. We previously hypothesized that it has two correlated scales, i.e. one on the psychosomatic effects of AF and the other on staff’s coping strategies in working with alarms. Objective. We aimed to validate the hypothesized structure of the CAFQa and thus underpin the instrument's construct validity. Methods. We conducted two independent studies with nurses and physicians from ICUs in Germany (N Study 1 = 265, N Study 2 = 1212). Responses to the questionnaires were analyzed using confirmatory factor analysis with the unweighted least-squares algorithm based on polychoric covariances. Convergent validity was assessed by participants' estimation of their own AF and exposure to false alarms in percent. Results. In both studies the chi-square test reached statistical significance (ꭓ 2 (26) = 44.932, p = 0.012 and ꭓ 2 (26) = 92.416, p < 0.001 for Study 1 and 2, respectively). Other fit indices suggested a good model fit (in both studies RMSEA < 0.05, SRMR < 0.08, RNI > 0.95, TLI > 0.95, and CFI > 0.995). Participants' mean scores correlated moderately with self-reported AF (r Study 1 = 0.45; r Study 2 = 0.53) and weakly with self-perceived exposure to false alarms (r Study 1 = 0.3; r Study 2 = 0.33). Conclusion. The questionnaire measures the construct of alarm fatigue as proposed in our previous study. Researchers and clinicians can rely on the CAFQa to measure the AF of nurses and physicians.
No takes yet. Share an insight, caveat, or question.
Wunderlich et al. (2024) conducted a cross-sectional in Alarm fatigue (n=1,477). Charité Alarm Fatigue Questionnaire (CAFQa) was evaluated on Construct validity (model fit) of the two-factor CAFQa model. The Charité Alarm Fatigue Questionnaire demonstrated good construct validity for its two-factor structure across two independent studies of ICU staff, with all fit indices indicating a good model fit.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: