Key result
O2 pulse curve slope, not absolute peak, correlates with peak stroke volume in Fontan patients.
Why the study?
Peak O2 pulse may be a poor marker of stroke volume in patients with a Fontan circulation, leading authors to evaluate whether O2 pulse slope better reflects exercise stroke volume.
Does the slope of the O2 pulse curve correlate with stroke volume during exercise in patients with a Fontan circulation?
Cohort (n=153)
Does the slope of the O2 pulse curve correlate with stroke volume during exercise in patients with a Fontan circulation?
The slope of the O2 pulse curve to peak exercise is a better reflection of peak stroke volume than a single peak O2 pulse value in patients with a Fontan circulation.
Answers are grounded in this paper and cite their sources.
O2 pulse slope may better reflect stroke volume than peak value in Fontan patients; hypothesis-generating and requires prospective validation.
Background Peak oxygen pulse (O 2 pulse=oxygen consumption/heart rate) is calculated by the product of stroke volume (SV) and oxygen extraction. It has been shown to be reduced in patients with a Fontan circulation. However, in the Fontan population, it may be a poor marker of SV. We propose that the slope of the O 2 pulse curve may be more reflective of SV during exercise. Methods We analysed cardiopulmonary exercise test data in 22 subjects with a Fontan circulation (cohort A) and examined the association between peak SV during exercise (aortic flow measured on exercise cardiac MRI), and O 2 pulse parameters (absolute O 2 pulse and O 2 pulse slopes up to anaerobic threshold (AT) and peak exercise). In a separate Fontan cohort (cohort B, n=131), associations between clinical characteristics and O 2 pulse kinetics were examined. Results In cohort A, peak aortic flow was moderately and significantly associated with O 2 pulseslope PEAK (r=0.47, p=0.02). However, neither absolute O 2 pulse AT nor O 2 pulse PEAK was significantly associated with peak aortic flow. In cohort B, O 2 pulseslope PEAK and O 2 pulseslope AT were not significantly associated with clinical parameters, apart from a weak association with forced vital capacity. Conclusion The slope of the O 2 pulse curve to peak exercise may be more reflective of peak SV in the Fontan population than a single peak O 2 pulse value.
No takes yet. Share an insight, caveat, or question.
Laohachai et al. (2023) conducted a cohort in Fontan circulation (n=153). O2 pulse slope vs. Absolute O2 pulse was evaluated on Association between peak stroke volume (aortic flow) during exercise and O2 pulse parameters (r=0.47, p=0.02). The slope of the O2 pulse curve to peak exercise was significantly associated with peak stroke volume (r=0.47, p=0.02) in patients with a Fontan circulation, unlike absolute peak O2 pulse.
Synapse has enriched 10 related papers. Consider them for comparative context: