Key result
Dynamic model updating improves postoperative mortality discrimination compared to nonupdating models.
Why the study?
Existing surgical aortic valve replacement mortality prediction models rarely account for temporal changes in practice and patient selection, and the impact of dynamic model updating methods on performance has not been rigorously tested.
Do dynamic model updating methods improve the prediction of postoperative mortality in patients undergoing surgical aortic valve replacement compared to a nonupdating model?
Cohort (n=44,546)
Yes
Do dynamic model updating methods improve the prediction of postoperative mortality in patients undergoing surgical aortic valve replacement compared to a nonupdating model?
Dynamic model updating, particularly the dynamic logistic state space model, improves accuracy, discrimination, and calibration for predicting postoperative mortality after surgical aortic valve replacement.
Answers are grounded in this paper and cite their sources.
Dynamic updating may refine SAVR mortality prediction; hypothesis-generating and requires prospective validation before practice change.
Objective: Clinical prediction models for surgical aortic valve replacement mortality, are valuable decision tools but are often limited in their ability to account for changes in medical practice, patient selection, and the risk of outcomes over time. Recent research has identified methods to update models as new data accrue, but their effect on model performance has not been rigorously tested. Methods: The study population included 44,546 adults who underwent an isolated surgical aortic valve replacement from January 1, 1999, to December 31, 2018, statewide in Pennsylvania. After chronologically splitting the data into training and validation sets, we compared calibration, discrimination, and accuracy measures amongst a nonupdating model to 2 methods of model updating: calibration regression and the novel dynamic logistic state space model. Results: statistic) than the nonupdating model: nonupdating (156.5), calibration regression (4.9), and dynamic logistic state space model (8.0). Overall accuracy (Brier score) was consistently better across both updating models: dynamic logistic state space model (0.0252), calibration regression (0.0253), and nonupdating (0.0256). Discrimination improved with the dynamic logistic state space model (area under the curve, 0.696) compared with the nonupdating model (area under the curve, 0.685) and calibration regression method (area under the curve, 0.687). Conclusions: Dynamic model updating can improve model accuracy, discrimination, and calibration. The decision as to which method to use may depend on which measure is most important in each clinical context. Because competing therapies have emerged for valve replacement models, updating may guide clinical decision making.
No takes yet. Share an insight, caveat, or question.
Pollack et al. (2023) conducted a cohort in surgical aortic valve replacement (n=44,546). Dynamic model updating (dynamic logistic state space model) vs. Nonupdating model was evaluated on Calibration, discrimination, and accuracy for postoperative mortality. Dynamic model updating using a dynamic logistic state space model improved discrimination for postoperative mortality (AUC 0.696) compared with a nonupdating model (AUC 0.685).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: