Key result
Ex vivo diffusion tensor imaging of congenital heart disease specimens revealed that tetralogy of Fallot and dextro-transposition of the great arteries with ventricular septal defect had a decreased helix angle gradient by -0.34°/% compared to those without.
Why the study?
Common congenital heart diseases exhibit structural and functional variations that may alter myocardial microstructure, prompting comparison of myocardial architecture using magnetic resonance DTI in preserved pathology specimens.
Does myocardial architecture measured by ex vivo DTI differ between various congenital heart diseases?
Observational (n=24)
No
Does myocardial architecture measured by ex vivo DTI differ between various congenital heart diseases?
Answers are grounded in this paper and cite their sources.
Ex vivo DTI reveals significant differences in myocardial microstructure, such as helix and sheet angles, among various congenital heart diseases, which may impact cardiac function and electrophysiology.
PURPOSE: Common types of congenital heart disease exhibit a variety of structural and functional variations which may be accompanied by changes in the myocardial microstructure. We aimed to compare myocardial architecture from magnetic resonance diffusion tensor imaging (DTI) in preserved pathology specimens. MATERIALS AND METHODS: Pathology specimens (n = 24) formalin-fixed for 40.8 ± 7.9 years comprised tetralogy of Fallot (TOF, n = 10), dextro-transposition of great arteries (D-TGA, n = 8) five with ventricular septal defect (VSD), systemic right ventricle (n = 4), situs inversus totalis (SIT, n = 1) and levo-TGA (L-TGA, n = 1). Specimens were imaged using a custom spin-echo sequence and segmented automatically according to tissue volume fraction. In each specimen T1, T2, fractional anisotropy, mean diffusivity, helix angle (HA) and sheet angle (E2A) were quantified. Pathologies were compared according to their HA gradient, HA asymmetry and E2A mean value in each myocardial segment (anterior, posterior, septal and lateral walls). RESULTS: TOF and D-TGA with VSD had decreased helix angle gradient by - 0.34°/% and remained symmetric in the septum in comparison to D-TGA without VSD. Helix angle range was decreased by 45°. It was associated with a decreased HA gradient in the right ventricular (RV) wall, i.e. predominant circumferential myocytes. The sheet angle in the septum of TOF was opposing those of the left ventricular (LV) free wall. Univentricular systemic RV had the lowest HA gradient (- 0.43°/%) and the highest HA asymmetry (75%). HA in SIT was linear, asymmetric, and reversed with a sign change at about 70% of the depth at mid-ventricle. In L-TGA with VSD, HA was asymmetric (90%) and its gradients were decreased in the septum, anterior and lateral wall. CONCLUSION: The organization of the myocytes as determined by DTI differs between TOF, D-TGA, L-TGA, systemic RV and SIT specimens. These differences in cardiac structure may further enlighten our understanding of cardiac function in these diverse congenital heart diseases.
No takes yet. Share an insight, caveat, or question.
Tous et al. (2020) conducted an observational in Congenital heart disease (Tetralogy of Fallot, Transposition of the great arteries, Systemic right ventricle, Situs inversus totalis) (n=24). Ex vivo cardiovascular magnetic resonance diffusion tensor imaging vs. Comparison between different congenital heart disease pathologies was evaluated on Helix angle gradient, helix angle asymmetry, and sheet angle. Ex vivo diffusion tensor imaging of congenital heart disease specimens revealed that tetralogy of Fallot and dextro-transposition of the great arteries with ventricular septal defect had a decreased helix angle gradient by -0.34°/% compared to those without.
Synapse has enriched 10 related papers. Consider them for comparative context: