Answers are grounded in this paper and cite their sources.
The feasibility of noninvasively assessing hemoglobin oxygen saturation of deep blood vessels in vivo by measuring blood T2* is investigated. Techniques for blood T2* measurements in major arteries and veins in the presence of pulsatile blood flow are presented and validated using a flow phantom. Images of multiple TEs were collected in a paired fashion. Cardiac triggering was used to eliminate image artifacts caused by pulsatile arterial blood flow. Using these techniques, it was found that the T2* of arterial blood (199 +/- 8 ms) is significantly greater than that of venous blood (108 +/- 6 ms) in 10 volunteers, consistent with the fact that the oxygen saturation level of arterial blood is much larger than that of venous blood. Various oxygen saturation levels were created in vivo in a pig and the blood T2* was shown to increase with oxygen saturation levels over a wide range. Preliminary results of this study indicate that it is feasible to assess local oxygen saturation by measuring blood T2* using the proposed techniques.
No takes yet. Share an insight, caveat, or question.
Li et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: