A new control algorithm for the three-phase buck rectifier with an input filter is developed. The algorithm employs a separate control loop for compensation of the input current displacement factor in steady-state, in addition to the standard output voltage regulation loop. The algorithm allows separate design of the input filter and of closed-loop output voltage control. The design procedure is explained and illustrated with an example. The algorithm is verified experimentally on a 1 kW, 100 kHz, three-phase isolated buck converter.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Hiti et al. (1994) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: