Key result
4D Flow CMR reveals BAV pressure recovery distance averages ~79 mm, exceeding accepted clinical norms.
Why the study?
Pressure recovery dictates the relationship between peak and net pressure drops in aortic stenosis, but inconsistency exists across centers on catheter positioning to capture net pressure drop.
Does non-invasive 4D Flow CMR accurately assess pressure recovery distance compared to invasive measurements in aortic stenosis models and patients?
Observational (n=32)
Yes
Does non-invasive 4D Flow CMR accurately assess pressure recovery distance compared to invasive measurements in aortic stenosis models and patients?
4D Flow CMR demonstrates that pressure recovery distance in aortic stenosis is often longer than the clinically accepted 40-50 mm, suggesting that standard catheterization may overestimate net pressure drop.
BACKGROUND: Decisions in the management of aortic stenosis are based on the peak pressure drop, captured by Doppler echocardiography, whereas gold standard catheterization measurements assess the net pressure drop but are limited by associated risks. The relationship between these two measurements, peak and net pressure drop, is dictated by the pressure recovery along the ascending aorta which is mainly caused by turbulence energy dissipation. Currently, pressure recovery is considered to occur within the first 40-50 mm distally from the aortic valve, albeit there is inconsistency across interventionist centers on where/how to position the catheter to capture the net pressure drop. METHODS: We developed a non-invasive method to assess the pressure recovery distance based on blood flow momentum via 4D Flow cardiovascular magnetic resonance (CMR). Multi-center acquisitions included physical flow phantoms with different stenotic valve configurations to validate this method, first against reference measurements and then against turbulent energy dissipation (respectively n = 8 and n = 28 acquisitions) and to investigate the relationship between peak and net pressure drops. Finally, we explored the potential errors of cardiac catheterisation pressure recordings as a result of neglecting the pressure recovery distance in a clinical bicuspid aortic valve (BAV) cohort of n = 32 patients. RESULTS: = 0.93) in the second phantom workbench. A linear correlation was observed between peak and net pressure drops, however, with strong dependences on the valvular morphology. Finally, in the BAV cohort the pressure recovery distance was 78.8 ± 34.3 mm from vena contracta, which is significantly longer than currently accepted in clinical practise (40-50 mm), and 37.5% of patients displayed a pressure recovery distance beyond the end of the ascending aorta. CONCLUSION: The non-invasive assessment of the distance to pressure recovery is possible by tracking momentum via 4D Flow CMR. Recovery is not always complete at the ascending aorta, and catheterised recordings will overestimate the net pressure drop in those situations. There is a need to re-evaluate the methods that characterise the haemodynamic burden caused by aortic stenosis as currently clinically accepted pressure recovery distance is an underestimation.
No takes yet. Share an insight, caveat, or question.
Fernandes et al. (2023) conducted an observational in Aortic valve stenosis (n=32). 4D Flow cardiovascular magnetic resonance (CMR) vs. Standard clinical assumption (40-50 mm) was evaluated on Pressure recovery distance from vena contracta. Non-invasive 4D Flow CMR revealed a pressure recovery distance of 78.8 ± 34.3 mm in bicuspid aortic valve patients, significantly longer than the clinically accepted 40-50 mm.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: