This investigation was motivated by the need for radiometric calibration of the Landsat-5 Thematic Mapper (TM) thermal band (Band 6), covering its 25 years of operation. Through fusion of environmental data and physical modeling, a vicarious calibration approach was implemented. Results, which were demonstrated to agree with data from previous field campaigns, indicate the Landsat-5 thermal band has been calibrated to better than 1 K over the 24 years in orbit. The data indicate the sensor exhibits a small gain error (approximately constant over time) and a bias shift for all data post-1999. The lifetime calibration error can be reduced to 0.49 K, in reference to a 300 K blackbody, by a pair of linear corrections. This study established that the methodology presented can be implemented to achieve a very high level of radiometric integrity, applicable to both historic and current data from remote thermal infrared systems.
No takes yet. Share an insight, caveat, or question.
Padula et al. (2010) studied this question.