Key result
Echocardiographic strain rate and tissue Doppler imaging significantly correlated with right ventricular end-diastolic pressure (e.g., strain rate a' r=-0.5, p=0.03), but not with systolic dP/dt.
Why the study?
Do echocardiographic measurements of right ventricular function correlate with invasive cardiac catheterisation parameters in paediatric congenital heart patients with two-ventricle physiology?
Observational (n=32)
Do echocardiographic measurements of right ventricular function correlate with invasive cardiac catheterisation parameters in paediatric congenital heart patients with two-ventricle physiology?
Strain rate and tissue Doppler imaging significantly correlate with right ventricular end-diastolic pressure in paediatric congenital heart patients, suggesting their potential as non-invasive alternatives to estimate RVEDP.
BACKGROUND: Newer echocardiographic techniques may allow for more accurate assessment of right ventricular function. Adult studies have correlated these echocardiographic measurements with invasive data, but minimal data exist in the paediatric congenital heart population. The purpose of this study was to evaluate echocardiographic measurements that correlate best with right ventricular systolic and diastolic catheterisation parameters. METHODS: Patients with two-ventricle physiology who underwent simultaneous echocardiogram and cardiac catheterisation were included in this study. Right ventricular systolic echocardiographic data included fractional area change, displacement, tissue Doppler imaging s' wave, global longitudinal strain, and strain rate s' wave. Diastolic echocardiographic data included tricuspid E and A waves, tissue Doppler imaging e' and a' waves, and strain rate e' and a' waves. E/tissue Doppler imaging e', tissue Doppler imaging e'/tissue Doppler imaging a', E/strain rate e', and strain rate e'/strain rate a' ratios were also calculated. Catheterisation dP/dt was used as a marker for systolic function and right ventricular end-diastolic pressure for diastolic function. RESULTS: A total of 32 patients were included in this study. The median age at catheterisation was 3.1 years (0.3-17.6 years). The DP/dt was 493±327 mmHg/second, and the right ventricular end-diastolic pressure was 7.7±2.4 mmHg. There were no significant correlations between catheterisation dP/dt and systolic echocardiographic parameters. Right ventricular end-diastolic pressure correlated significantly with strain rate e' (r=-0.4, p=0.02), strain rate a' (r=-0.5, p=0.03), and E/tissue Doppler imaging e' (r=0.4, p=0.04). CONCLUSION: Catheterisation dP/dt did not correlate with echocardiographic measurements of right ventricular systolic function. Strain rate and tissue Doppler imaging analysis significantly correlated with right ventricular end-diastolic pressure. These values should be further studied to determine whether they may be used as an alternative method to estimate right ventricular end-diastolic pressure in this patient population.
No takes yet. Share an insight, caveat, or question.
Nadorlik et al. (2017) conducted an observational in biventricular congenital heart disease (n=32). Echocardiography vs. Cardiac catheterisation was evaluated on Correlation between echocardiographic measurements and right ventricular systolic (dP/dt) and diastolic (RVEDP) catheterisation parameters (r=-0.5, p=0.03). Echocardiographic strain rate and tissue Doppler imaging significantly correlated with right ventricular end-diastolic pressure (e.g., strain rate a' r=-0.5, p=0.03), but not with systolic dP/dt.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: