Key result
Higher atrial fibrillatory rate associates with longer and nighttime-onset AF episodes on implantable monitors.
Why the study?
The study aimed to characterize atrial fibrillatory rate extracted from continuously monitored AF patients as a function of episode duration and onset time.
Does atrial fibrillatory rate vary with episode duration and onset time in patients with continuously monitored atrial fibrillation?
Cohort (n=99)
Does atrial fibrillatory rate vary with episode duration and onset time in patients with continuously monitored atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Data from implantable cardiac monitors indicates that higher atrial fibrillatory rates are associated with longer AF episodes and nighttime onset.
The aim of this study is to characterize atrial fibrillatory rate (AFR) extracted from a cohort of continuously monitored atrial fibrillation (AF) patients as function of episode duration and onset time. The f-wave signal used to compute the AFR was extracted from a single lead ECG strip of the AF episodes stored in an Implantable Cardiac Monitor (ICM) in a cohort of 99 patients. The f-wave signals were obtained from 1400 AF episodes using a spatiotemporal QRST cancellation process and the AFR was estimated as the fundamental frequency of a model fitted to the extracted f-waves. We studied the relationship between AFR and episode duration and episode onset time, respectively. AFR (median (interquartile range)) was significantly lower (p-value<0.05) in short episodes (<20 min) (5.15 (0.66) Hz) than in longer episodes (5.30 (0.74) Hz). AFR was significantly higher for episodes with onset time at night (00-06) (5.34 (0.82) Hz) than for episodes with onset during the day (10-20) (5.21 (0.70) Hz). Significant differences were also found between the relative AFR (ratio between the AFR and the average AFR of the patient) and episode duration (Short: 99.2 (9.3) %; Long: 100.0 (8.9) %). Data extracted from ICMs shows that that nighttime AF onset and longer duration AF episodes are more common in patients with higher AFR.
No takes yet. Share an insight, caveat, or question.
Saiz-Vivó et al. (2021) conducted a cohort in Atrial fibrillation (n=99). Implantable Cardiac Monitor (ICM) monitoring was evaluated on Atrial fibrillatory rate (AFR) in longer vs short (<20 min) episodes (p=<0.05). Atrial fibrillatory rate extracted from implantable cardiac monitors was significantly higher in longer AF episodes (5.30 vs 5.15 Hz) and those with nighttime onset (5.34 vs 5.21 Hz; p<0.05).
Synapse has enriched 10 related papers. Consider them for comparative context: