May 28, 2026Journal of Electrical and Electronic Engineering1 citationsOpen Access

Efficiency of Multispectral Pyrometer Technology in the Infrared Spectral Band According to Planck's Law on the Real Body in the Case of Oxidized Steels

RERatianarivo EzekelÉcole Supérieure Polytechnique d'AntsirananaTRTiavina RazafindratsiraCentre National de la Recherche Appliquée au Developpement RuralRERASTEFANO EliséeUniversity of Antananarivo

Key Points

  • This research aims to analyze the efficiency of multispectral pyrometry in measuring temperatures of oxidized steels based on Planck's law.
  • Theoretical analysis of thermal radiation and emissivity using Planck's law.
  • Development of nonlinear models for multispectral processing methods.
  • Comparison of monochromatic, bichromatic, and multispectral pyrometry approaches.
  • Multispectral pyrometry shows improved reliability against emissivity variations, outperforming traditional methods.
  • Significant improvements in linearity of temperature detection across the infrared spectral band were observed.
  • Mid-infrared measurements provide greater stability and accuracy for temperature detection in oxidized steel.

Abstract

This research is based on a theoretical analysis of thermal radiation, the fundamental laws of Planck and Kirchhoff, and multispectral processing methods using nonlinear models. Accurate high-temperature measurement is a major challenge in many scientific and industrial fields, including thermal processes, metallurgy, energy, and fundamental research. Planck’s law gives de relation between radiation, temperature ant wavelength. That low can be used to determine temperature by pyrometry method. Besides Planck’s law for the black body multiplied by the emissivity will gives the expression of the real body. Uncertainty in emissivity is the main source of error in conventional pyrometric measurements. In our case, the polynomial model of emissivity only goes up to the second order. To reduce the influence of emissivity and improve measurement reliability, several approaches have been developed, including monochromatic, bichromatic, and multispectral pyrometry based on Planck's law. The characteristics of chromatic luminance in the near and mid-infrared bands highlight the high potential of pyrometry for measuring high temperatures in complex environments. Compared to traditional approaches, this pyrometry technology offers greater robustness to variations in emissivity and environmental uncertainties. Luminance across the infrared spectral band and a temperature range provides improved linearity. This linearity highlights the strength of using infrared radiation for remote temperature sensing. The mid-infrared zone offers greater stability and a closer relationship between luminance, temperature, and wavelength in temperature detection for oxidized steel.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ezekel et al. (2026) studied this question.

synapsesocial.com/papers/6a17dc063fad632b0f9d8a6ahttps://doi.org/10.11648/j.jeee.20261403.11
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Temperature measurements using multicolor pyrometry in thermal radiation heating environments2014 · 52 citations
  2. 2Temperature Measurements of Diesel Fuel Combustion With Multicolor Pyrometry2010 · 54 citations
  3. 3Real time multispectral high temperature measurement: Application to control in the industry2006 · 74 citations
  4. 4Determination of the spatial temperature distribution from combustion products: A diagnostic study2013 · 18 citations
  5. 5All-fiber-optic infrared multispectral radiometer for measurements of temperature and emissivity of graybodies at near-room temperature2004 · 11 citations