Key result
Resolute Onyx stent demonstrates low thrombosis rates, making it a promising candidate for short DAPT.
Why the study?
Increasing complexity regarding coronary anatomy and comorbidities in patients undergoing PCI requires dedicated devices.
Is the Resolute Onyx zotarolimus-eluting stent safe and effective for patients undergoing percutaneous coronary intervention?
Is the Resolute Onyx zotarolimus-eluting stent safe and effective for patients undergoing percutaneous coronary intervention?
The Resolute Onyx zotarolimus-eluting stent demonstrates excellent safety and efficacy, particularly low stent thrombosis rates, making it suitable for complex PCI and short DAPT regimens.
May inform stent choice for short DAPT candidates; hypothesis-generating and requires prospective RCTs before practice change.
Introduction: The increasing complexity of patients undergoing percutaneous coronary intervention (PCI) regarding both coronary anatomy and comorbidities requires dedicated devices. The Resolute Onyx (R-Onyx, Medtronic, CA, USA) stent is a novel durable polymer zotarolimus-eluting stent (ZES) promising better deliverability, increased radiopacity and lower thrombogenicity.Areas covered: In this review, we discuss device features, preclinical evidence, and clinical studies including patients treated with R-Onyx. The BIONYX and Onyx ONE studies were two major landmark trials demonstrating non-inferiority of R-Onyx as compared to other latest generation devices. We also elaborate on alternative innovations in drug-eluting stent (DES) technology and how R-Onyx fits into this field.Expert opinion: R-Onyx is designed to address the challenges of contemporary PCI, but evidence on its clinical performance is largely derived from studies on older generation devices from the ZES family. Nonetheless, all clinical studies on R-Onyx consistently show excellent outcomes, with particularly low rates of stent thrombosis, making it a promising candidate for short dual antiplatelet regimens. In addition, R-Onyx is available with a wide range of stent diameters allowing accurate sizing for both very small and very large coronary vessels.
No takes yet. Share an insight, caveat, or question.
Blum et al. (2020) conducted a review in Coronary artery disease. Resolute Onyx Zotarolimus eluting coronary stent system was evaluated. The Resolute Onyx zotarolimus-eluting stent demonstrated excellent clinical outcomes with low rates of stent thrombosis, making it a promising candidate for short dual antiplatelet regimens.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: