October 1, 1974Circulation191 citationsOpen Access

Detection of Residual Myocardial Function in Coronary Artery Disease Using Post-extra Systolic Potentiation

View Full Paper
SDS. DykePCPeter F. CohnRGRichard Gorlin

Key Points

  • To evaluate whether post-extra systolic potentiation during left ventriculography can safely detect latent, reversible contractile function in patients with coronary artery disease.
  • Performed quantitative left ventriculography in 15 patients with coronary artery disease (including seven with significant asynergy) and three normal controls (total N=18).

Structured PICO

Does post-extra systolic potentiation (PESP) during left ventriculography detect latent residual contractile function in patients with coronary artery disease?

P
Population
18 subjects total, comprising 15 patients with coronary artery disease (CAD) (including 7 with significant asynergy) and 3 normal controls.
I
Intervention
Post-extra systolic potentiation (PESP) via a single extra-systole introduced by an R-wave coupled stimulator (R-stimulus interval averaged 398 msec, average mA 2.4) during quantitative left ventriculography.
C
Comparator
Baseline contractile function prior to PESP.
O
Outcome
Improvement in segmental axis shortening, ejection fraction, and mean rate of circumferential fiber shortening.surrogate

Post-extra systolic potentiation during left ventriculography is a safe and effective method to detect latent residual contractile function in ischemic myocardium.

Abstract

Improved global or segmental wall motion following revascularization suggests potential reversibility of ischemic left ventricular dysfunction in coronary artery disease (CAD). This study evaluates the effectiveness of post-extra systolic potentiation (PESP) to detect latent residual contractile function. Quantitative left ventriculography was performed in 15 patients with CAD (including seven with significant asynergy) and in three normal controls. During the ventriculogram, a single extra-systole was introduced by an R-wave coupled stimulator (R-stimulus interval averaged 398 msec, with an average mA of 2.4). PESP improved segmental axis shortening in 51 of 55 normal axes and 15 of 17 hypokinetic or akinetic axes. It also increased both ejection fraction and mean rate of circumferential fiber shortening in 17 of 18 patients. No significant arrhythmia occurred with this technique. A single interposed beat with PESP in one ventriculogram is a safe, effective method to detect residual potential contractile function in myocardium that may be hypokinetic or akinetic under conditions of the study.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dyke et al. (1974) studied this question.