Key result
Ballistocardiography machine learning estimates cardiac output with ~30% error compared to invasive monitoring.
Why the study?
Prehospital emergency medicine lacks a reliable automated non-invasive method for monitoring circulation, and conventional cardiac output monitors are not feasible or practical in that setting.
Does non-invasive ballistocardiography accurately estimate cardiac output compared to invasive arterial blood pressure monitoring in healthy subjects?
Observational (n=20)
No
Does non-invasive ballistocardiography accurately estimate cardiac output compared to invasive arterial blood pressure monitoring in healthy subjects?
Non-invasive ballistocardiography combined with machine learning shows feasibility for estimating cardiac output, offering a potential future tool for prehospital emergency monitoring.
Supports further development of non-invasive cardiac output tools; leaves open validation in patients and clinical settings.
There is no reliable automated non-invasive solution for monitoring circulation and guiding treatment in prehospital emergency medicine. Cardiac output (CO) monitoring might provide a solution, but CO monitors are not feasible/practical in the prehospital setting. Non-invasive ballistocardiography (BCG) measures heart contractility and tracks CO changes. This study analyzed the feasibility of estimating CO using morphological features extracted from BCG signals. In 20 healthy subjects ECG, carotid/abdominal BCG, and invasive arterial blood pressure based CO were recorded. BCG signals were adaptively processed to isolate the circulatory component from carotid (CCc) and abdominal (CCa) BCG. Then, 66 features were computed on a beat-to-beat basis to characterize amplitude/duration/area/length of the fluctuation in CCc and CCa. Subjects' data were split into development set (75%) to select the best feature subset with which to build a machine learning model to estimate CO and validation set (25%) to evaluate model's performance. The model showed a mean absolute error, percentage error and 95% limits of agreement of 0.83 L/min, 30.2% and - 2.18-1.89 L/min respectively in the validation set. BCG showed potential to reliably estimate/track CO. This method is a promising first step towards an automated, non-invasive and reliable CO estimator that may be tested in prehospital emergencies.
No takes yet. Share an insight, caveat, or question.
Svensøy et al. (2024) conducted an observational in Healthy subjects (n=20). Ballistocardiography (BCG) based machine learning model vs. Invasive arterial blood pressure based CO (pulse contour analysis) was evaluated on Mean absolute error of cardiac output estimation in the validation set (L/min) (95% CI -2.18-1.89). A machine learning model using ballistocardiography features estimated cardiac output with a mean absolute error of 0.83 L/min and a percentage error of 30.2% compared to invasive monitoring.