Key result
Surface ECG criteria distinguished right-sided from left-sided pulmonary vein origin of spontaneous atrial premature complexes with 82% sensitivity and 100% specificity.
Why the study?
Can quantitative analysis of the surface ECG accurately localize the pulmonary vein origin of spontaneous atrial premature complexes in patients referred for atrial fibrillation ablation?
Observational (n=30)
Can quantitative analysis of the surface ECG accurately localize the pulmonary vein origin of spontaneous atrial premature complexes in patients referred for atrial fibrillation ablation?
Quantitative analysis of the surface ECG can accurately distinguish right-sided from left-sided pulmonary vein origins of spontaneous atrial premature complexes, even when superimposed on T waves.
ECG criteria may aid PV trigger localization in AF ablation; leaves open prospective validation before clinical adoption.
We have shown that pacemapping from each of the pulmonary veins reveals unique surface ECG characteristics. However, application of these criteria to spontaneous atrial premature complexes is often difficult because of obscuration by the prior T wave. We hypothesized that the pulmonary vein of origin of spontaneous atrial premature complexes can be determined by measuring characteristics of the P wave whether or not the P wave was superimposed on the prior T wave. We analyzed 58 spontaneous atrial premature complexes of known pulmonary vein origin in 30 patients referred for atrial fibrillation ablation. The origin of all the atrial premature complexes was documented by detailed, intracardiac multipolar catheter mapping. Based on previous work, the criteria for distinguishing right-sided from left-sided pulmonary vein origin of atrial premature complex includes: (1) P wave duration < 120 ms; (2) P wave amplitude in lead I > 0.05 mV; and (3) P wave amplitude in leads II/III > 1.25. The criteria to separate superior from inferior pulmonary veins included the sum of the P wave amplitude in all the inferior leads greater than 0.3 mV. The combination of the P wave duration < 120 ms and the ratio of the P wave amplitude in leads II/III > 1.25, distinguished right-sided from left-sided pulmonary vein origin of spontaneous atrial premature complexes with a sensitivity of 82% and specificity of 100%. The sum of the P wave amplitude in leads II, III, and aVF > 0.3 mV distinguished superior from inferior pulmonary vein of origin with a sensitivity of 39% and specificity of 73%. The pulmonary vein origin of spontaneous atrial premature complexes can often be localized using careful quantitative analysis of the surface ECG despite superimposition of the P wave upon the T wave. Separation of right-sided from left-sided pulmonary vein origin of spontaneous atrial premature complexes can be determined with good specificity and sensitivity, while the ability to distinguish inferior from superior pulmonary vein origin is limited.
No takes yet. Share an insight, caveat, or question.
Rajawat et al. (2004) conducted an observational in Atrial fibrillation with spontaneous atrial premature complexes (n=30). Surface ECG P wave criteria vs. Intracardiac multipolar catheter mapping was evaluated on Localization of pulmonary vein origin of spontaneous atrial premature complexes. Surface ECG criteria distinguished right-sided from left-sided pulmonary vein origin of spontaneous atrial premature complexes with 82% sensitivity and 100% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: