Answers are grounded in this paper and cite their sources.
OBJECTIVE: The aim of this study was to describe a novel limb-sparing technique for the management of feline bone neoplasia using a custom-made femoral endoprosthesis in combination with a total knee replacement (TKR) prosthesis. METHODS: Two cats with distal femoral bone tumours underwent pelvic limb salvage procedures with custom-made implants designed from patient-specific computed tomography images to replace the distal femur and the stifle. In case 1, the first-generation implant was a combination of a cemented femoral endoprosthesis with a uniaxial hinged cemented TKR prosthesis. Due to aseptic loosening of the endoprosthesis, revision was performed with a second-generation femoral endoprosthesis modified with a short intramedullary peg and a lateral bone plate for immediate stability. In case 2, a third-generation endoprosthesis with an intramedullary peg and two orthogonal bone plates for immediate stability, combined with a custom-designed rotationally hinged cemented TKR prosthesis, was used. Clinical and radiographic follow-up was recorded. RESULTS: After revision surgery in case 1 and with the third-generation implant in case 2, no complications were encountered. Both cats showed minor mechanical restriction of stifle range of motion and good clinical long-term outcome without local tumour recurrence. CONCLUSION: The combination of a femoral endoprosthesis and a TKR prosthesis can be a viable alternative for distal femoral limb salvage in cats.