Key result
Greater PTFV1 is linked to reduced LV peak filling rate in patients with normal perfusion.
Why the study?
PTFV1 indicates left atrial overload, but whether it is associated with left ventricular diastolic function remains undetermined.
Is P-wave terminal force in lead V1 (PTFV1) associated with left ventricular diastolic function in patients with preserved ejection fraction and no significant perfusion abnormalities?
Cross-Sectional (n=158)
No
Is P-wave terminal force in lead V1 (PTFV1) associated with left ventricular diastolic function in patients with preserved ejection fraction and no significant perfusion abnormalities?
In patients with preserved ejection fraction and no significant perfusion abnormalities, an increased P-wave terminal force in lead V1 is independently associated with impaired left ventricular diastolic function as assessed by gated SPECT.
Answers are grounded in this paper and cite their sources.
PTFV1 may flag diastolic impairment in preserved EF without ischemia; hypothesis-generating and requires prospective validation.
P-wave terminal force in lead V1 (PTFV1) is a marker of increased left atrial (LA) overload. Whether PTFV1 is associated with left ventricular (LV) diastolic function remains undetermined. We tested the hypothesis that PTFV1 is associated with LV diastolic parameters derived from gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with no significant perfusion abnormalities.The study population included 158 patients with preserved ejection fraction and no significant perfusion abnormalities. The amplitude and duration of the P-wave negative phase in lead V1 were measured using an electrocardiogram, and PTFV1 was calculated. The peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained as LV diastolic parameters using gated SPECT.PTFV1 showed a weak correlation with the LA volume index (r = 0.31; P < 0.001). Significant associations were observed between PTFV1 and PFR (r = -0.27; P < 0.001) and 1/3 MFR (r = -0.26; P = 0.001). A multivariate linear regression analysis showed that age (β = -0.26; P < 0.001), LV end-diastolic volume index (β = -0.27; P = 0.001), and PTFV1 (β = -0.15; P = 0.036) were significant factors associated with PFR. Moreover, male gender (β = -0.16; P = 0.041), LV mass index (β = -0.17; P = 0.046), and PTFV1 (β = -0.17; P = 0.022) were significant factors associated with the 1/3 MFR.PTFV1 is associated with LV diastolic function, as derived from gated SPECT in patients with no significant perfusion abnormalities.
No takes yet. Share an insight, caveat, or question.
Fukuda et al. (2022) conducted a cross-sectional in Known or suspected coronary artery disease with no significant perfusion abnormalities (n=158). P-wave terminal force in lead V1 (PTFV1) was evaluated on Correlation between PTFV1 and peak filling rate (PFR) (r = -0.27, p=<0.001). P-wave terminal force in lead V1 was significantly associated with left ventricular diastolic function parameters, including peak filling rate (r = -0.27), in patients with no significant perfusion abnormalities.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: