Tensiometers, gypsum blocks, Watermark blocks and an electromagnetic conductivity meter were evaluated for their response to changes in soil moisture content. Tensiometers and Watermark blocks had similar responses, but the blocks operated better than tensiometers in drier soil. Gypsum blocks did not respond until some threshold moisture content was reached. The electromagnetic conductivity meter responded to changes in moisture content in fine-textured soil, but it did not respond in sandy soil.
No takes yet. Share an insight, caveat, or question.
Hanson et al. (2000) studied this question.