Why the study?
This study sought to investigate the role of postprocedural troponin elevations in mortality prediction after transcatheter aortic valve implantation and to define the threshold where postprocedure myocardial injury determines mortality.
Does a >18.3-fold increase in postprocedural troponin predict long-term mortality in patients undergoing transcatheter aortic valve implantation?
Does a >18.3-fold increase in postprocedural troponin predict long-term mortality in patients undergoing transcatheter aortic valve implantation?
A postprocedural high-sensitivity troponin T elevation of >18.3-fold above the upper reference limit is a strong independent predictor of long-term mortality after transcatheter aortic valve implantation.
May support post-TAVI risk stratification; leaves open whether troponin thresholds should guide management or trials.
Background This study sought to investigate the role of postprocedural troponin elevations in mortality prediction after transcatheter aortic valve implantation and to define the threshold at which clinically relevant postprocedure myocardial injury determines mortality. Methods and Results A total of 1333 consecutive patients with transcatheter aortic valve implantation with available postprocedural high-sensitivity cardiac troponin T measurements were included in the analysis. The threshold at which postprocedure myocardial injury determines long-term mortality was identified using restricted cubic spline analysis. A >18.3-fold increase of troponin above the upper reference limit was identified as threshold for relevant postprocedure myocardial injury. Associations remained significant in a landmark analysis between 30 days and 2 years (hazard ratio [HR], 1.61, [95% CI, 1.13-2.28]; P=0.01), after adjusting for known confounders (adjusted HR, 1.90 [95% CI, 1.40-2.57]; P<0001), and in subgroups of patients with coronary artery disease (adjusted HR, 2.17 [95% CI, 1.44-3.29]; P<0.001), renal dysfunction (adjusted HR, 1.88 [95% CI, 1.35-2.62]; P<0.001), and intermediate/high surgical risk (adjusted HR, 2.70 [95% CI, 1.40-5.22]; P=0.003). Conclusions This study determined a troponin threshold for the identification of patients at increased mortality risk after transcatheter aortic valve implantation. The proposed definition of postprocedure myocardial injury advances risk stratification in patients with transcatheter aortic valve implantation and may assist in postprocedural patient management.
No takes yet. Share an insight, caveat, or question.
Schindler et al. (2021) studied this question.