A low-noise, ultra-short linear-cavity distributed feedback fiber laser (DFB-FL) with extremely narrow linewidth is presented. The FL has a total length of 17 mm, which is, to our knowledge, the shortest DFB-FL being reported. It has a measured linewidth of merely 250 Hz without active stabilization. It has a polarization beat frequency of 101 MHz, which is several times lower than that of most FLs. The relaxation oscillation frequency and relative peak are 110 kHz and −76.5 dB/Hz, respectively. The FL exhibited low-noise characteristics, with an intensity noise of −107 dB/Hz at 1 MHz. Due to low dopant concentration of the EDF and low splice loss with ordinary single-mode fibers, the net insertion loss amounts to only 0.45 dB. Such low pump power loss greatly enhances the capability of multiplexing a large number of FL sensors. Thus, these ultra-short DFB-FLs open up new opportunities for the development of compact-sized point sensor array systems for large-scale high sensitivity sensing applications.
No takes yet. Share an insight, caveat, or question.
Wong et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: