Key result
Enoxaparin anti-Xa concentrations were drawn incorrectly 77% of the time, often resulting in unsupported dose adjustments and repeat laboratory testing.
Why the study?
Are enoxaparin anti-Xa concentrations correctly drawn and utilized for dose adjustments in clinical practice?
Cohort (n=59)
No
Are enoxaparin anti-Xa concentrations correctly drawn and utilized for dose adjustments in clinical practice?
Enoxaparin anti-Xa concentrations are frequently drawn incorrectly in clinical practice, leading to inappropriate dose adjustments that could compromise patient safety.
Answers are grounded in this paper and cite their sources.
Incorrect anti-Xa timing was associated with unsupported enoxaparin adjustments; hypothesis-generating and should not yet change practice.
Background Anti-Xa monitoring is utilized to measure the extent of anticoagulation in certain patient populations receiving enoxaparin. It is essential to accurately obtain this pharmacodynamic marker for safe and effective anticoagulation management. Objectives To determine the frequency of correctly drawn anti-Xa concentrations in accordance with predefined institutional criteria and to determine the number of dose adjustments implemented based on incorrectly drawn anti-Xa concentrations. Methods This was a retrospective, single-center, cohort study among adult patients who received treatment doses of enoxaparin with measured anti-Xa concentrations. Patients were excluded if they were pregnant, on hemodialysis, or received prophylactic dosing. Anti-Xa levels were defined as correctly measured if they were drawn 3 to 5 hours after the dose during steady state concentrations. Descriptive statistics were performed and analyzed via SPSS software. Results Overall, 203 patients were reviewed and 59 patients with 74 anti-Xa levels were included. The majority of anti-Xa levels (57/74; 77%) were drawn incorrectly and often resulted in collection of repeat anti-Xa samples. There were 12 documented dose adjustments and approximately 42% (5/12) were based on incorrectly drawn anti-Xa levels. Anti-Xa levels were within target range approximately 45% of the time. Conclusions Enoxaparin anti-Xa concentrations are frequently drawn incorrectly and dose adjustments are often performed based on these unsupported anti-Xa levels. This may present a potential risk to compromise patient safety.
No takes yet. Share an insight, caveat, or question.
Kufel et al. (2017) conducted a cohort in Patients receiving treatment doses of enoxaparin requiring anti-Xa monitoring (n=59). Enoxaparin anti-Xa monitoring was evaluated on Frequency of incorrectly measured anti-Xa levels. Enoxaparin anti-Xa concentrations were drawn incorrectly 77% of the time, often resulting in unsupported dose adjustments and repeat laboratory testing.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: